SETTING UP AND USING THE eFORCE 150
Mortise Cylinder Replacement
1. Remove battery cover and battery pack; see "Battery Replacement" section for details.
2. Remove the two (2) #10-32 x 5/8 screws from the inside bottom of trim (Figure 17).
3. Lift the eForce 150 up and off the mounting bracket, being careful not to lose spindle located in output hub on back of the unit.
CAUTION: There are wires connecting the housing and back plate assembly.
These must be handled with care to not cause damage.
4. Remove eight (8) #10-32 x 5/8" screws on the back of the eForce 150 (Figure 18), and gently lift back plate off housing.
5. Remove cylinder using included Cylinder Nut Tool; fit new mortise cylinder into housing and secure with
supplied Cylinder Retaining Ring and tighten using Cylinder Nut Tool (Figure 19).
NOTE: Dummy cylinders cannot be used.
6. Carefully replace back plate and screws. Do not overtighten.
7. Place eForce 150 back on door in reverse order of removal.
8. Enter a known user code to ensure the eForce 150 is functioning correctly, if not refer to "Troubleshooting" section.
FIGURE 17

TROUBLESHOOTING

Green light comes on, but lever will not retract latch-bolt.
1. Check the eForce 150 body connection with lock/latch mechanism.
2. Check cylinder tailpiece length & alignment
(see installation instructions).
3. Check for proper door preparation (refer to door templates).
No lights come on when pushbuttons are depressed.
1. Ensure Visual Keypad Feedback is set to Enable (PCC 32).
2. Check battery polarity.
3. Check battery pack voltage (6V nominal).
4. Check battery pack terminal connection.
No tones sound when pushbuttons are depressed.
1. Ensure Audible Keypad Feedback is set to Enable (PCC 31).
2. Check battery polarity.
3. Check battery pack voltage (6V nominal).
4. Check battery pack terminal connection.
FIGURE 18
Approved 2023-11-13
FIGURE 19
Factory default codes not working.
1. Perform a Reset to return all values to default;
see "Programming Information" section.
2. Reprogram Master and Emergency codes, followed by User codes.
User codes not working.
1. Ensure Lockout Code has not been entered.
2. Check battery power (operator may be in blackout
mode). See "Battery Replacement" section.
3. Check cylinder tailpiece length & alignment
(see installation instructions).
Operator stays unlocked.
1. Ensure Passage Code has not been entered.
2. Check cylinder tailpiece length & alignment
(see installation instructions).
3. Check eForce battery and connection.
4. Ensure battery cover is on, hex screw is tight
and mortise cylinder key is removed.
7 of 8