Download Print this page

Assa Abloy Adams Rite eForce 150 Installation Instructions And User Manual page 3

Keyless entry

Advertisement

INSTALLATION
Hand the eForce 150
1. Install handle in desired direction & secure with Set Screw from parts kit (Figure 9).
2. For Model 3090-02, skip to "Install Mortise Cylinder" section.
3. Check rotation direction in Table 1 and change as needed. Unit is shipped in the clockwise configuration, viewed from the rear.
FIGURE 9
Table 1. Handing Setup for 3090-01 Version*
Device Type
SVR
Mortise Latch
CVR
RIM
*3090-02 cannot change rotation direction. To change rotation, use a flat screwdriver to adjust the output hub located
on the back of the 3090-01 (Figure 10). Turn approximately 270° opposite the direction you want it to actuate.
Example: If the hub is rotating clockwise, turn the hub with a screwdriver 270° clockwise; the hub will then rotate counterclockwise.
Install Mortise Cylinder
See "Mortise Cylinder Replacement" section (page 7), Steps 4-6, for detailed instruction.
Install Optional RSK-3090 Kit
For applications that require a remote activation switch, plug the RSK-3090 connector into the back of the eForce 150 (Figure 11).
NOTE: Device will unlock when wires make contact through a normally open dry contact.
Left Hand Reverse
Clockwise
Counter-Clockwise
Clockwise
Counter-Clockwise
FIGURE 11
Approved 2023-11-13
FIGURE 10
Right Hand Reverse
Clockwise
Clockwise
Clockwise
Counter-Clockwise
3 of 8