You can now screw the adjusted MF Removal Tool into the center of the M id Unit (1).
Once the tool has been tightened in position you will be able to ease the Mid Unit off the
drawbar and out of the cabinet (2).
Note: Take note of the cable positions
Brown = Positive (+)
Blue = Negative (-)
With the Mid Unit removed you can clearly
see the Drawbar (3) that the Mid Unit is
mounted on allowing it to float in the cabi-
net.
The contents of this document and associated files contain confidential information that is propriety to B&W
Group Ltd., and are intended solely for the purpose of servicing the product. The information is intended for use
by service technicians familiar with electronic products. No part of the contents should be supplied or published
elsewhere.