Replace the coolant

· Drain off the coolant :
–Keep the motorcycle upright by parking stand.
–Lay a liquid dish under the engine.
–Remove the water drainage bolt. Because the
heat radiation system is connected, so all the
coolant may flow out from that drainage port.
–Re-assemble the drainage bolt when the coolant
was completely drained off.
·Fill up the coolant:
–The coolant need be filled up from heat radiator and expansion tank :
–Open the water tank cover of heat radiator as figure 2 shown, then fill up the coolant.
–Obser ve from the tank cover of heat radiator to confirm the coolant is full, filling-up while
squeezing the water tube for exhausting the air till it full, then screw up the cover.
–After screwed up the tank cover, start engine for 30 seconds to make sure the coolant
spread to each part need it.
–Stop the engine, and open the water tank cover again when the engine was cooled down to
check if the coolant is really full, in case the level fell down, fill up again till full again,
repeat this action till it fulfilled, this action need be repeated if necessar y.
–Finally remove the black rubber cap 3 on expansion tank till the coolant level reached
position between scale marks UPPER and LOWER.
Fill up by running water is not allowed, or it may damage the cooling system.
Mixture of coolant from different specification is not allowed due to various ingredient.