Replace the coolant

·
Drain off the coolant
Keep the motorcycle upright by parking stand
Lay a liquid dish under the engine
Remove the water drainage bolt Because the
heat radiation system is connected so all the
coolant may flow out from that drainage port
Re assemble the drainage bolt when the coolant
-
was completely drained off
·
Fill up the coolant
The coolant need be filled up from heat radiator and expansion tank
Open the water tank cover of heat radiator as figure 2 shown then fill up the coolant.
Observe from the tank cover of heat radiator to confirm the coolant is full filling up while
squeezing the water tube for exhausting the air till it full then screw up the cover
After screwed up the tank cover start engine for 30 seconds to make sure the coolant
spread to each part need it
Stop the engine and open the water tank cover again when the engine was cooled down to
,
check if the coolant is really full in case the level fell down fill up again till full again
repeat this action till it fulfilled this action need be repeated if necessary
Finally remove the black rubber cap 3 on expansion tank till the coolant level reached
position between scale marks UPPER and LOWER
Fill up by running water is not allowed or it may damage the cooling system
Mixture of coolant from different specification is not allowed due to various ingredient.
.
.
.
,
.
,
,
.
,
.
.
!
Warning
,
Water drainage bolt
:
,
,
,
Water filling up port
-
,
-
.
,
.
.
53