SNMP Monitoring

SNMP monitoring is available to help with troubleshooting your EB4-1U
chassis. If you are using an SNMP agent to monitor your network, you
must first configure your SNMP network with information from the MIB
file included with the EB4-1U system.
You must configure your EB4-1U chassis correctly, or it will not be
visible to your network. More information on configuring your SNMP
settings is available in

Audible Alarms

The EB4-1U chassis is equipped with two temperature sensors. One is
located in the front of the chassis and the other is located in the back of
the chassis. You can configure the high and low temperature sensor
limits for each sensor individually. Information on changing these values
is available in the
When the temperatures inside the
chassis are within their assigned
limits, both of the Sensor Alarm
Lights
will
glow
temperature
ever
assigned limits, the Sensor Alarm
Light for the sensor detecting the
failure will glow red and sound an
audible alarm. Press the red Alarm
Reset Button to silence and reset the
audible alarm.