3.5

Program Mode

Program Mode provides a View Sensor Status menu to check operational and configuration
parameters. Program Mode also provides for adjustment of the AutoSpan Level, Gas Factor, Gas
Type and Range, and Serial ID. Additionally, it includes the Set Sensor Gain, Restore Factory
Defaults, and Signal Output Check diagnostic functions.
The Program Mode menu items appear in the order presented below:
View Sensor Status
Set AutoSpan Level
Set Gas Type and Range
Set Gas Factor
Set Serial ID
Set Sensor Gain
Signal Output Check
Restore Defaults
3.5.1
Navigating Program Mode
From Normal Operation, enter Program Mode by holding the magnet over PGM2 for 10
seconds. Note, the "" prompt will show that the magnetic switch is activated during the 10
second hold period. The OLCT 700/710 will enter Program Mode and the display will scroll the
first menu item "View Sensor Status". To advance to the next menu item, hold the magnet over
PGM1 or PGM2 while the current menu item's text is scrolling. At the conclusion of the text scroll
the ""prompt ("" for PGM2 or "" for PGM1) will appear, and immediately remove the
magnet. The OLCT 700/710 will advance to the next menu item. Repeat this process until the
desired menu item is displayed. Note, PGM1 moves the menu items from right to left and PGM2
moves the menu items from left to right.
To enter a menu item, hold the magnet over PGM1 or PGM2 while the menu item is scrolling. At
the conclusion of the text scroll the ""prompt ("" for PGM2 or "" for PGM1) will appear,
continue to hold the magnet over PGM1 or PGM2 for an additional 3-4 seconds to enter the
selected menu item.
If there is no magnet activity while the menu item text is scrolling (typically 4 repeated text scrolls),
the OLCT 700/710 will automatically revert to Normal Operation.
3.5.2
View Sensor Status
View Sensor Status displays all current configuration and operational parameters including:
sensor type, software version number, detection range, AutoSpan level, days since last
AutoSpan, estimated remaining sensor life, gas factor, gas type, input voltage, 4-20 output,
active counts, reference counts, and detector ambient temperature.
NP700IRIMEN
Revision E.0
INFRARED GAS DETECTOR FOR COMBUSTIBLE AND CO
700 IR Series
2
GASES
USER MANUAL
23