Table of Contents

Advertisement

Quick Links

GAS LASER
Operator's Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GAS LASER and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Teledyne GAS LASER

  • Page 1 GAS LASER Operator’s Manual...
  • Page 2: Table Of Contents

    Border Color Indicators Image Screen Mode Warranty and Repair Quick Press Features Long Press Features Contact Information GPS Indicators Border Color Indicators Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 3: Overview

    This manual supersedes all previous manuals for this instrument. Doc No. 16086 Rev A, Gas Laser Operator Manual | Date: October 21, 2021 | Copyright © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved. Doc No. 16162 Rev A, GAS LASER Operator Manual...
  • Page 4: Warnings & Definitions

    Operator’s Manual Warnings & Definitions Safety and Warning Information Read this manual before using the Gas Laser instrument and accessories. Users must read, understand and follow the instructions for operation and maintenance. Failure to do so can result in serious injury.
  • Page 5: Avertissements Et Définitions

    Avertissements et définitions Informations sur les dangers, la sécurité et les avertissements Lisez ce manuel avant d’utiliser l’instrument Gas Laser et ses accessoires. Les utili- sateurs doivent lire, comprendre et suivre les instructions d’utilisation et d’entretien. Le non-respect de cette consigne peut entraîner des blessures graves.
  • Page 6: Hazardous Safety And Warning Information

    Class 2(II) Consult instructions for local regulations. Lithium Ion battery Do not stare into beam. IP54 Ingress Protection Avoid direct eye exposure. Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 7: Informations Sur Les Dangers, La Sécurité Et Les Avertissements

    Classe 2(II) d’emploi Ne pas fixer le faisceau. Batterie au lithium-ion Éviter l’exposition directe IP54 Indice de protection des yeux. Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 8 Laser Calibration Drift A normal characteristic of tunable diode lasers is that the wavelength calibration can drift slowly over time. The Gas Laser has a built in Self-Test/ Calibration feature to automatically maintain proper calibration. PPM-M (Parts Per Million Meter) The product of the methane concentration times the thickness of the plume.
  • Page 9: Specifications

    Class I, Zone 2, AEx ic op is IIA T4 Gc 94DEG (at 6.0mm image circle) Class I, Division 2, Group D Intrinsically Safe Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 10: Instrument And Accessories

    - LED on the front indicates charging status - Replaces the original from - Use only with HPN 105756 Complete Kit/Carrying Case Battery Pack Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 11: Battery, Charger, Charging Procedure

    Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 12: Charging Procedure

    Red icon indicates low capacity remaining/ always plug the charger into a time to charge surge-protected outlet. Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 13: Operating The Gas Laser

    On all screens, the middle par cet instrument. button shuts down the instrument press activation. when pressed and held for 3 seconds. Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 14: Self Test

    Self Tested may need to be redone. If instrument does not successfully perform a Self Test after three attempts, contact Teledyne GMI for assistance. Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 15: Scan Screen Mode

    - Red, fast flashing – detection exceeds alarm level methane detected. Operator may disable flashing through the MENU. Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 16: Image Screen Mode

    - Red, fast flashing – detection exceeds alarm level methane detected. Operator may disable flashing through the MENU. Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 17: Working With The Menu Items

    - Over saturation of signal and follow the instructions in the - Low battery troubleshooting guide on page 29. Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 18: Alarm Level

    Bluetooth (BLE) The Gas Laser instrument is equipped with Bluetooth 4.2 BLE to support future features and mobile applications. Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 19: Wifi

    Portal (see page 24). Portal. attempting a connection Changing factory default AP SSID and AP Password is recommended. Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 20: Data Logging

    3. Select the BACK button when complete NOTICE NOTICE: Time Zone Offset can be set using the Configuration Portal (see page 24). Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 21: Peak History

    • WiFi Status (on/off) • GPS Status • Self Test (status) • Contact Information for • Bluetooth Status (off/on) the manufacturer. Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 22: File Access

    GAS LASER Operator’s Manual File Access The Gas Laser stores data on an internal SD memory card. The data files can be downloaded or accessed in the following ways: - USB File Transfer - WiFi connection to Configuration Portal (details below)
  • Page 23: Wifi

    Delete button. NOTICE NOTICE: The deleting of files & folders is irreversible. Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 24: Configuration Portal

    NOTICE When Finished With Configuration Portal: - Close the web browser - Disable WiFi AP Mode Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 25: How Does The Gas Laser Measure Gas

    AVERTISSEMENT : Le Gas Laser Gas Laser. The reflected light is collected and processed so the Gas Laser est capable de balayer les fenêtres can report methane concentrations in parts-per-million-meter or PPM-M.
  • Page 26: Scanning With The Gas Laser

    The Gas Laser may be used to scan any structure or place that has gas service. gas. However, scanning through Some of the common venting points of a house are shown below.
  • Page 27: Meter

    (i.e., ground, building, etc.) must in the soil, frost conditions in to the right of the IR laser beam. reflect the infrared beam back. winter). Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 28: Long Range Scanning

    Re-scan the area from a slightly different angle. The laser light is selective to methane, and will not false-alarm on other hydrocarbons. Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
  • Page 29: Troubleshooting

    GAS LASER Operator’s Manual Troubleshooting CAUTION With its advanced design, the Gas Laser is one of the most reliable meth- CAUTION: Only a qualified Gas Laser ane detection instruments available. Should you experience problems, there repair technician should attempt re- is most likely a simple cause.
  • Page 30: Maintenance

    GAS LASER Operator’s Manual Maintenance In order to maintain the Gas Laser in good working condition, the following maintenance should be performed as indicated: Maintenance Item Frequency CAUTION Clean outer surfaces with damp rag As needed CAUTION: Only a qualified...
  • Page 31: Contact Information

    #03-08 Viva Business Park TX 77249, USA Scotland, UK Singapore 469003 Tel: +1-713-559-9200 Tel.: +44 (0) 141 812 321 1 Tel.: +65 84282741 www.teledynegasandflamedetection.com Doc No. 16162 Rev A, GAS LASER Operator Manual © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.