Teledyne 700 IR Series Instruction Manual page 48

Infrared gas detector for combustible and co2 gases
Table of Contents

Advertisement

700 IR Series
INFRARED GAS DETECTOR FOR COMBUSTIBLE AND CO
GASES
USER MANUAL
ATEX Marking:
Ingress Protection:
Safety Approvals:
Warranty:
Environmental Specifications
Operating Temperature:
Storage Temperature:
Operating Humidity:
Operating Pressure Range:
Mechanical Specifications
Dimensions :
OLCT 700
OLCT 710
Weight:
Electrical Specifications
Input Voltage:
Power Consumption:
Inrush current:
RFI/EMI Protection:
Cable Requirements:
Power/Analog:
Serial Output:
I/O Protection:
42
2
II 2 GEx db IIB+H
2
(Tamb=-40° to +70°C)
NEMA 4X, IP66
ATEX
CE Marking
SIL2 FMEDA Rating
Plug-in sensor – 2 years
Transmitter – 2 years
-40°F to +158F°; -40°C to +70°C
-58°F to +158°F; -50°C to +70°C
0-100% RH (Non-condensing)
Atmospheric ± 10%
7"H x 2.2" Dia.; 178mmH x 65mm Dia.
13.74"H x 5.0"W x 5.12"D; 349mmH x 127mmW x
130mmD
2.5 lbs; 1.14 kg (OLCT 700 only)
7.4 lbs; 3.36 kg (OLCT 710 w/aluminum j-box)
16.4 lbs; 7.44 kg (OLCT 710 w/stainless steel j-box)
11-30 VDC
Normal operation = 68mA (<1.7 watt)
Maximum = 85mA (2 watts)
0.67A @ 24V
Complies with EN 50270 for Type 2 device
3-wire shielded câble
Maximum distance is 4000 meters feet with 14 AWG
2-wire twisted-pair shielded cable specified for RS-485 use
Maximum distance is 1200 meters to last detector
Over-Voltage, Miss-wiring, EMI/RFI Immunity
T4 Gb
NP700IRIMEN