List Of Memory Switch Settings (For Mechanism) - Brother BM-2000 Instruction Manual

Table of Contents

Advertisement

No.
Name
427
X-over detection - cloth plate
raising position correction
430
Lower material presser
500
Nozzle glue width
522
Operation when upper roller
stops
531
Feeding amount after and
detection
532
Feed distance after gluing
stops
601
Warning level for low amount
of glue

3.5.5 List of memory switch settings (for mechanism)

No.
Name
11
Treadle mode for bonding
preparation
86
Treadle – Number of speed
steps
250
Max. feed speed
252
Feed speed during reverse
mode
273
Feed motor excitation while
paused
274
Pump motor excitation while
paused
550
Target temperature for
melter
551
Target temperature for pump
552
Target temperature for
nozzle
553
Max pump speed
554
Time out for temperature
control
555
Wait duration after reaching
target temperature
556
Wait time after cartridge
replacement
560
Temperature of melter during
sleep mode
561
Temperature of pump during
sleep mode
562
Temperature of nozzle
during sleep mode
565
Temperature of melter during
boot
566
Minimum duration for melter
heating during boot
571
Minimum melter pressure
572
Maximum melter pressure
3 USING THE OPERATION PANEL AND SWITCHES
Setting
Correction distance for cloth plate
raising position when an X-over seam
is detected
Lower material presser
OFF: Disabled ON: Enabled
Gluing width of installed nozzle
Upper roller pressure after paused
OFF: Pressure off
ON: Pressure on
Feed amount after detecting lower
material end (mm)
Feed distance until feed stops after
gluing stops
OFF: Does not stop
Amount of remaining glue for
displaying warning dialog
Setting
Selection of treadle operation method
during preparation for gluing
Number of steps in the variable speed
range for the treadle
Max. feed speed
Feed speed during reverse mode
Feed motor excitation status when
stopped
Pump motor excitation status when
stopped
Target temperature for melter
Target temperature for pump
Target temperature for nozzle
Pump speed upper limit
Temperature control timeout time
Wait time after target temperature is
reached
Wait time after cartridge replacement
Melter temperature during sleep mode
Pump temperature during sleep mode
Nozzle temperature during sleep
mode
Melter temperature during startup
Melter heating time lower limit value
during startup
Melter pressurization lower limit
Melter pressurization upper limit
BM-2000
Setting range
Unit
-11.0 - 20.0 [mm]
0.1
OFF, ON
-
6 - 10 [mm]
2
OFF, ON
-
0.0 - 25.0 [mm]
0.5
OFF,
1
1 - 100[mm]
1 - 5[%]
1
Setting range
Unit
1 - 2
1
OFF,
1
2 - 30
0.5 - 5.0
0.1
[m/min]
0.5 - 5.0
0.1
[m/min]
OFF, ON
-
OFF, ON
-
80 - 145[°C]
5
80 - 145[°C]
5
80 - 145[°C]
1
5 - 50[rpm]
1
10 - 60[min]
5
3 - 15[min]
1
5 - 30[min]
1
OFF,
5
60 - 145[°C]
OFF,
5
60 - 145[°C]
OFF,
1
60 - 145[°C]
80 - 145[°C]
5
10 - 60[min]
1
100 - 200
10
[KPa]
200 - 300
10
[KPa]
Initial
value
0.0
ON
8
OFF
0.0
OFF
3
Initial
value
2
20
5.0
1.0
ON
OFF
90
120
125
42
30
5
15
70
60
80
125
15
100
300
25

Advertisement

Table of Contents
loading

Table of Contents