3.2.1 Parameter list

Some of the parameters are set once for each program (and are common to all steps in that program), and other parameters are set
individually for each step.
[Program parameters]
Parameter
Glue thickness
(Thickness of the glue)
Nozzle space
(Clearance
between
nozzle and the roller under
nozzle)
Comment
(Comment string for program
which is displayed on the
screen)
[Step parameters]
Parameter
Upper roller feed speed
Lower roller feed speed
Upper cloth glue-free width
Lower cloth glue-free width
Anti stop mark
Setting range
50
200 [um]
-
the
0.10
2.50 [mm]
-
Up to 24 alphanumeric
characters
Setting range
0.50 - 5.00 [m/min]
0.50 - 5.00 [m/min]
-50 - +50
-50 - +50
1 - 10
3 USING THE OPERATION PANEL AND SWITCHES
Unit
10 [um]
0.05 [mm]
--
Unit
0.01 [m/min]
0.01 [m/min]
1
1
1
BM-2000
Initial value
80 [um]
0.50 [mm]
Not input
Initial value
1.00 [m/min]
1.00 [m/min]
0
0
1