Adjusting The Upper Cloth And Lower Cloth Sensor Amplifiers; Summary - Brother BM-2000 Instruction Manual

Table of Contents

Advertisement

12 STANDARD ADJUSTMENTS

12.3 Adjusting the upper cloth and lower cloth sensor amplifiers

12.3.1 Summary

Adjust the upper cloth and lower cloth sensor amplifiers.
This bonding machine uses the following three types of amplifier.
Upper cloth sensor amplifier FS-N11MN (1)
Lower cloth sensor amplifier FS-N11MN (2)
End detection sensor amplifier FS-N11N (3)
The names of the amplifier parts are shown below.
Operation indicator
Sub-screen (green display)
Set button (SET)
Fiber hold lever
NOTE:
Do not touch the end detection sensor amplifier.
If the sensor emitters, the areas around them or the reflectors become dirty, the amount of incoming light will drop, and
there may not be enough incoming light to set the necessary light intensity. In such cases, clean the affected areas and
then carry out adjustments.
90
Main screen, incoming light display (red display)
Manual buttons(◀▶)
(1)
(2)
(3)
Power select switch
BM-2000
Mode button
(MODE)
Preset button
(PRESET)
Dust cover