List Of Memory Switch Settings (For Operators) - Brother BM-2000 Instruction Manual

Table of Contents

Advertisement

3 USING THE OPERATION PANEL AND SWITCHES

3.5.4 List of memory switch settings (for operators)

No.
Name
208
Pump speed during test
mode
211
Automatic discharge time in
test mode (F1)
212
Automatic discharge time in
test mode (F2)
213
Automatic discharge time in
test mode (F3)
214
Automatic discharge time in
test mode (F4)
215
Automatic discharge time in
test mode (F5)
221
Assignment No. for F1 key
222
Assignment No. for F2 key
223
Assignment No. for F3 key
224
Assignment No. for F4 key
225
Assignment No. for F5 key
226
Assignment No. for F6 key
231
Program/Step changing
method
255
Feed speed decrease rate
256
Feed speed increase rate
301
Auto sleep mode
302
Elapsed time before entering
auto sleep mode
400
Speed of edge control roller
401
Upper edge controller
402
Lower edge controller
411
Nozzle lever - Glue position
adjustment
413
Nozzle lever
421
X-over bonding
422
Sensitivity of the X-over
bonding detection sensor
424
X-over bonding - Cloth plate
lowering amount
426
X-over detection - cloth plate
lowering position correction
24
Setting
Pump speed during test mode
Glue discharge time when F1 is
pressed during test mode
Glue discharge time when F2 is
pressed during test mode
Glue discharge time when F3 is
pressed during test mode
Glue discharge time when F4 is
pressed during test mode
Glue discharge time when F5 is
pressed during test mode
Program number selected when F1 is
pressed at the home screen
Program number selected when F2 is
pressed at the home screen
Program number selected when F3 is
pressed at the home screen
Program number selected when F4 is
pressed at the home screen
Program number selected when F5 is
pressed at the home screen
Program number selected when F6 is
pressed at the home screen
1: Change step with knee switch
2: Change step with knee switch and
change program with Op hand
switch
3: Change program with knee switch
Upper roller speed deceleration rate
when feed speed adjustment switch is
moved down
Upper roller speed acceleration rate
when feed speed adjustment switch is
moved up
Automatic sleep mode
Standby time until automatic sleep
mode is entered
Edge control roller rotation speed
Upper edge controller
OFF: Disabled ON: Enabled
Lower edge controller
OFF: Disabled ON: Enabled
Adjustment value for glue position
Nozzle lever motor speed
X-over detection function
ON: Enabled, OFF: Disabled
X-over detection sensor sensitivity
Distance that cloth plate is lowered
when an X-over seam is detected
(AUTO: Lowering amount = clearance
setting value)
Correction distance for cloth plate
lowering position when an X-over
seam is detected
BM-2000
Setting range
Unit
5 - 50 [rpm]
5
10 – 1800 [s]
5
10 – 1800 [s]
5
10 – 1800 [s]
5
10 – 1800 [s]
5
10 – 1800 [s]
5
OFF,
1
1 - 30
OFF,
1
1 - 30
OFF,
1
1 - 30
OFF,
1
1 - 30
OFF,
1
1 - 30
OFF,
1
1 - 30
1 - 3
1
-10.0 - 0.0[%]
0.1
0.0 - 10.0[%]
0.1
OFF, ON
-
15 - 60 [min]
15
10 - 300 [rpm]
10
OFF, ON
-
OFF, ON
-
-120 - 120
4
60 - 300 [rpm]
10
OFF, ON
-
0.5 - 2.0
0.1
AUTO,
0.02
0.1 - 2.00 [mm]
-11.0 - 20.0 [mm]
0.1
Initial
value
40
30
80
600
180
180
OFF
OFF
OFF
OFF
OFF
OFF
1
0.0
0.0
ON
30
50
ON
ON
0
300
OFF
1.0
AUTO
0.0

Advertisement

Table of Contents
loading

Table of Contents