Troubleshooting guide:

Problem
No BIM data on instrument readout;
BIM does not light up.
No BIM data on instrument readout;
BIM display is scanning "BUS"
No BIM data on instrument readout;
BIM has a steady dot lit.
BIM display shows ":"
Possible cause
PWR wire does not have power.
GND wire is not properly grounded.
Power/data harness is damaged.
Module is damaged.
CAN Interface cable is not connected
FiTech CAN outputs are not enabled
Interface cable is not connected.
Interface cable is loose.
On VHX systems, the BIM display for
this channel is disabled.
Data cable is damaged or connected
improperly.
Another module on the bus is damaged.
Connect to a location that has +12V key-on power.
Connect to a different ground location.
Inspect harness. Repair or replace any damaged
areas.
Return for service. (see instructions)
Connect the supplied CAN interface cable between
the BIM unit and the ECU's CAN output.
Enable CAN outputs using the FiTech handheld
(see pg. 7)
Connect the supplied harness between the BIM
unit and the instrument system control box.
Ensure both ends of the cable are seated securely.
Follow instructions in VHX manual to enable the
BIM display screen.
Inspect and replace harness or power/data
harness.
Inspect other modules on the data bus.
[10]
Solution
MAN #650819A