Caution -
LED at the front of the system unit should not be lit and the fan should not be
running. When the system power switch is in the Standby position, and the AC
power cord remains connected to a power outlet, hazardous AC voltage is still
present in the power supply primary. Do not attempt to service the power supply
under these conditions. Disconnect the AC power cord prior to handling the power
supply. When servicing any other system component, the AC power cord should
remain connected and poses no safety hazard.
2. Locate the VSIMM slot on the main logic board.
See Figure 11–5.
Figure 11–5
3. Place an antistatic mat, shiny side up, next to the system unit.
The mat is supplied with the replacement VSIMM.
4. Remove the faulty VSIMM.
Grasp the VSIMM at its top corners and carefully wiggle it free from its connector
(see Figure 11–6). Be careful not to touch any of the components on the VSIMM.
5. Place the VSIMM on the antistatic mat.
SPARCclassic/SPARCclassic X/SPARCstation LX Service Manual ♦ Revision A, November 1993
114
Verify that the system power switch is in the Standby position. The green
VSIMM Slot Location

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparcclassic xSparcstation lx