de
Immediately on receipt check the product for damage in transport. Damaged products must not be installed or commis-
sioned.
5.1.

PLACE OF ERECTION

en
5.1.1.

Ambient conditions

Ambient temperature: +15 °C to +25 °C.
Do not expose to severe temperature fluctuations.
Store or erect the system indoors at a location dust-free, dry and not exposed to sunlight, free from shaking and vibra-
cs
tion.
Do not store or erect the system close to corrosive or aggressive chemical substances, solvents, moisture or dirt.
Avoid exposure to direct sunlight.
da
5.1.2.

Remove the packaging material

i
Store the packaging material for any necessary disassembly, dispatch or storage.
es
1. Remove the cover of the wooden case, and also the four side walls.
2. Unscrew the two retaining brackets from the pallet, and remove the brackets.
3. Remove the restraining strap.
4. With assistance by a second person, lift the pre-setting device and position it at the place of erection.
fi
5.1.3.

Remove the transport restraint

A
fr
i
Before initial commissioning remove the transport restraint and store it for any necessary disassembly, dispatch or storage.
1. Using a hexagon key L-wrench size 3 mm, undo the screw on the tower.
2. Remove the guard plate.
hr
3. Screw the screw finger-tight into the tower.
6.

Commissioning

hu
6.1.

CONNECTING THE

6.1.1.

power supply

B
it
i
Use only the power supply unit supplied.
1. Connect a low-power plug to the power supply unit.
lt
2. Connect the low-voltage plug of the power supply unit to the socket at the rear of the base body.
3. Connect the power plug to the electrical mains (110 - 230 V voltage).
»
Before commissioning, connect to the Compressed air supply [} Page 42].
nl
6.1.2.

Compressed air supply

C
1. Connect the source of compressed air via a compressed air hose to the socket at the rear of the base body.
pl
»
A service unit (pre-set to 5 bar) is connected internally.