Installing The Slides; Marking The Columns - HP NetServer LH 6000 Installation Manual

Table of Contents

Advertisement

All manuals and user guides at all-guides.com
Chapter 13

Installing the Slides

The following steps and illustrations describe how install slides for mounting a HP
NetServer.

Marking the Columns

Mark the mounting location of the HP NetServer and mounting holes on each
column of the rack as described (see Figure 13-2).
NOTE
The EIA unit marks are stamped in the sheet metal of the
columns. the rack template to mark the correct holes for
mounting (on all four columns).
Marking Front Columns
Mark the slide mounting holes on the front columns.
1. Mark the baseline (bottom) of the HP NetServer at an EIA unit mark on the
column.
2. Hold the bottom of the rack template at the baseline. Mark the top of HP
NetServer (8 EIA units counted up from the baseline).
3. Mark the slide screw mounting holes (holes 20 and 22 counted up from the
baseline).
4. Mark the second front column by repeating steps 1 through 3.
Marking Rear Columns
Mark the slide mounting holes on the inside faces of the rear columns.
1. Mark the baseline (bottom) of the HP NetServer at an EIA unit mark on the
column.
2. Hold the bottom of the rack template at the baseline. Mark the top of HP
NetServer (8 EIA units counted up from the baseline).
3. Mark the slide mounting hole (hole 21 counted up from the baseline).
4. Mark the second rear column by repeating steps 1 through 3.