6. Units overview
24-Channel 350 Ω Bridge Conditioning Unit
No. Description
1 Input connectors 01 – 24
2 Real-Time applications digital output connector
3 Power/Data connectors
The B24-350 Unit supports Wheatstone bridge based sensors (full, half and quarter bridges) with
an internal 350 ohm termination for quarter bridges DC or AC supplied, force cells, torque cells,
displacement sensors, piezo-resistive and piezo-capacitive sensors, differential voltage inputs, RTD or
potentiometer conditioning in a single, 24-channel input unit.
Its multiple bridge conditioning options, selectable per channel, support true durability load data
acquisition test campaigns.
It allows standardization of bridge-based sensors on a single unit.
Housing and channel signal ground are connected internally.
Maximum power consumption in most demanding operating conditions:
• 24x Voltage: 25.2 W
• 24x Full Bridge: 24.5 W
• 24x Half Bridge/Quarter Bridge: 19.5 W
6-10
User Manual Simcenter SCADAS RS system, Simcenter Testlab
© 2023 Siemens