Table of Contents

Advertisement

Quick Links

User Manual
Simcenter SCADAS RS
Simcenter Testlab

Advertisement

Table of Contents
loading

Summary of Contents for Siemens Simcenter SCADAS RS

  • Page 1 User Manual Simcenter SCADAS RS Simcenter Testlab...
  • Page 2 No one is permitted to use these Marks without the prior written consent of Siemens or the owner of the Marks, as applicable. The use herein of third party Marks is not an attempt to indicate Siemens as a source of a product, but is intended to indicate a product from, or associated with, a particular third party.
  • Page 3: Copyright

    © 2023 Siemens Digital Industries Software. All rights are explicitly reserved. All information in this manual, including additional drawings and technical descriptions, remains the property of Siemens. No part of this publication may be used (otherwise than for the use of this product), photocopied, duplicated, translated and/or disclosed to third parties without explicit prior written permission by Siemens.
  • Page 4: Table Of Contents

    Hazards and residual risks ────────────────────── Residual risks ────────────────────────────── Safety provisions ─────────────────────────── Product safety ────────────────────────────── Covering ──────────────────────────────── Electrical safety ───────────────────────────── Components and accessories ─────────────────────── Safety precautions ──────────────────────────── Built-in Li-Ion battery ───────────────────────── System overview User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 5 ───────────────────────────── Connecting cables Daisy chaining ─────────────────────────── 10-1 Handling sensor plugs ──────────────────────── 10-2 System connectivity Host interface ─────────────────────────── 11-1 Synchronization interface ────────────────────── 11-2 Security ────────────────────────────── 11-2 Operating Simcenter SCADAS RS User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 6 ───────────────────────────────── Wiring Notes 13-11 ───────────────────────────── Maintenance and calibration Cleaning ────────────────────────────── 14-1 Calibration ───────────────────────────── 14-2 Software Simcenter SCADAS RS Recorder App and Configuration App ─────── 15-1 Simcenter Testlab Neo ──────────────────────── 15-1 Firmware updates 15-1 ──────────────────────────── Troubleshooting Solving common problems ────────────────────── 16-1...
  • Page 7 Contents End of life and Disposal Disposal at end-of-life ──────────────────────── 19-1 Notes Remarks ────────────────────────────── 20-1 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 8 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 9: Version History

    Version history Version Date Comment 1.0 May 2021 First issue 2.0 January 2023 Second issue 2.1 June 2023 Updated second issue 2.2 December 2023 Updated second issue User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 10 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 11: General Terms

    Simcenter SCADAS RS system. Disclaimer Siemens does not guarantee any work caused by or arising out of the failure of the user to comply with the instructions or recommendations in this User Manual. Siemens reserves the right to change parts at any moment without prior notice or direct notification.
  • Page 12: Licenses And Trademarks

    • Contact your local Siemens representative for further instructions. Transportation of goods In case you need to return parts to Siemens for repair, you are requested to contact your local Siemens representative first. You will be informed about the applicable procedures and follow-up.
  • Page 13: About This Manual

    2. About this manual Usage and availability This manual provides information for the safe and correct use of the Simcenter SCADAS RS system. Make sure that you carefully read the instructions to use the Simcenter SCADAS RS system in accordance with its purpose and intended use.
  • Page 14: Related Documentation

    There is a risk of major damage to the equipment or major personal injury. Related documentation This User Manual describes the hardware that makes up the Simcenter SCADAS RS system. This system can only be used in combination with other Simcenter named products that have their own dedicated manuals.
  • Page 15: Introduction

    This chapter gives generic information about the Simcenter SCADAS RS system. The purpose of this chapter is to inform the user about what the Simcenter SCADAS RS system is meant for and what the products comprise of. It is the responsibility of the user to use the Simcenter SCADAS RS system in accordance with its purpose and intended use.
  • Page 16: Use In Accordance With The Purpose

    Simcenter SCADAS RS systems must only be used for the specific purpose described above. Any attempt to alter or modify a Simcenter SCADAS RS system or its use for any other purpose will be considered not to be in accordance with its purpose and regarded as misuse. Misuse may result in injury to personnel or serious damage to equipment.
  • Page 17: Safety Information

    • Simcenter SCADAS RS products are safe for indoor and outdoor use. • Simcenter SCADAS RS products can safely be used to an altitude of 5,000 m above sea-level. • Simcenter SCADAS RS products are safe for use in a wet location.
  • Page 18: Covering

    4. Safety information • Simcenter SCADAS RS products are rated Pollution degree 3 of the intended environment. • The degree of ingress protection of Simcenter SCADAS RS products according to IEC 60529 is IP66 and IP67. Covering During normal operation – i.e. unused connectors are properly capped – exposure to any hazards is reduced to a minimum.
  • Page 19: Built-In Li-Ion Battery

    • When not using UPS Units for a longer period of time, it is best to store them at room temperature and with a battery charge level between 40% and 80%. • Do not exceed 50 °C storage temperature to avoid excessive degradation of battery capacity. User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 20 4. Safety information User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 21: System Overview

    PC or a PC is connected to the REC Unit, Simcenter Testlab Neo software can be used for data acquisition. The Simcenter SCADAS RS Recorder App is used to control the recording application embedded on the REC Unit.
  • Page 22 A configuration topology consists of a Signal Conditioning Unit and a PC. This setup is intended for configuring a Signal Conditioning Unit and a simple measurement only. DC power is delivered by a Siemens approved AC/DC power adapter. Since there is no UPS Unit, this setup is not robust. Configuration topology User Manual Simcenter SCADAS RS system, Simcenter Testlab ©...
  • Page 23 Never connect a network or a PC to a daisy chain with Conditioning Units that are connected to a REC Unit. This can generate an error in the system, an error of a measurement or cause problems in the network or to the PC. User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 24 The Recorder Unit does not support Signal Conditioning Units that are positioned between the top UPS Unit and the REC Unit. This is also important to guarantee proper power management. User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 25: Units Overview

    6. Units overview This section shows all units that are part of the Simcenter SCADAS RS System. Each unit will be described in more detail in the next sections. Unit Product code and description SCRS-UPS Uninterruptable Power Supply Unit SCRS-REC...
  • Page 26 Product code and description SCRS-S24 24-Channel Sensor Conditioning Unit SCRS-U12 12-Channel Universal Sensor Conditioning Unit SCRS-U12-E 12-Channel Universal Signal Conditioning Unit Extended Bandwidth SCRS-ECAT ® EtherCAT Unit SCRS-TC20 Unit Thermocouple Conditioning Unit User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 27: General Dimensions And Weight

    General dimensions and weight General dimensions and weight Item Value Dimensions [W x H x D] 254 mm x 85 mm x 90 mm Weight Approx. 1.8 kg User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 28: Uninterruptable Power Supply Unit

    SCADAS RS units with their typical power consumption. Through power management by an on-board application, it indicates via LEDs if it can provide sufficient power to downstream Simcenter SCADAS RS units at the operational temperature range. If more power is needed, additional UPS units can easily be added to the Simcenter SCADAS RS configuration.
  • Page 29 • Very quick discharge, at least 20 s, for full load below –20 °C, 3/4 load below –25 °C and 1/4 load below –35 °C. • Quick discharge, at least 2 minutes, for full load below –15 °C. User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 30: Recorder Unit

    The REC unit can be operated in several ways: • Fully autonomous. Start/stop recording by pushing the Mode button. A long push (15 s) will bring REC Unit to its factory defaults. User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 31 During this time, a recording cannot be started and the Mode button turns insensitive. The REC Unit's status LED will turn solid green when it is recording data (refer to REC Unit status LED). User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 32: Digital Pulse And Can Bus Conditioning Unit

    Maximum power consumption in most demanding operating conditions: • Base consumption 14.5 W. • Up to additional 10.2 W for 4x loaded CAN buses. • Up to additional 8 W for 3x loaded Pulse inputs. User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 33: Channel 120 Ω Bridge Conditioning Unit

    Housing and channel signal ground are connected internally. Maximum power consumption in most demanding operating conditions: • 24x Voltage: 25.2 W • 24x Full Bridge: 24.5 W • 24x Half Bridge/Quarter Bridge: 19.5 W User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 34: 24-Channel 350 Ω Bridge Conditioning Unit

    Housing and channel signal ground are connected internally. Maximum power consumption in most demanding operating conditions: • 24x Voltage: 25.2 W • 24x Full Bridge: 24.5 W • 24x Half Bridge/Quarter Bridge: 19.5 W 6-10 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 35: 24-Channel Sensor Conditioning Unit

    Housing and channel signal ground are connected internally. Maximum power consumption in most demanding operating conditions: • 24x Mixed: 20 W • 24x Voltage: 17 W • 24x ICP: 15 W User Manual Simcenter SCADAS RS system, Simcenter Testlab 6-11 © 2023 Siemens...
  • Page 36: 12-Channel Universal Signal Conditioning Unit

    It allows standardization of measurement equipment on a single unit, and offers channel to channel isolation. Maximum power consumption in most demanding operating conditions: • 12x Mixed: 19 W • 12x ICP: 13.5 W 6-12 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 37: 12-Channel Universal Signal Conditioning Unit Extended Bandwidth

    Its multiple signal conditioning options, selectable per channel, support true multi-physics test campaigns. It allows standardization of measurement equipment on a single unit, and offers channel to channel isolation. User Manual Simcenter SCADAS RS system, Simcenter Testlab 6-13 © 2023 Siemens...
  • Page 38 U12-E Sharp FIR Alias rejection is always better than 110 dB.   Maximum power consumption in most demanding operating conditions: • 12x Mixed: 19 W • 12x ICP: 13.5 W 6-14 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 39: Ethercat® Unit

    ® It allows to digitally connect the Simcenter SCADAS RS to the Ethercat bus. It provides a low latency data output to the Ethercat master. The specific task for a durability application is to provide a digital data output to test rig controllers, like MTS or IST (INSTRON).
  • Page 40: Tc20 Thermocouple Conditioning Unit

    2 Real-Time applications digital output connector 3 Power/Data connectors The TC20 Unit enables Simcenter SCADAS RS to condition up to 20 thermocouples of different types. These temperature sensors consist of two leads of different materials that have a single junction that is used as temperature sensing point.
  • Page 41 Thermocouple leads are terminated with a standardized Miniature connector. Each of these connectors are based on the same materials as the thermocouple leads and the connectors are color coded for each type. User Manual Simcenter SCADAS RS system, Simcenter Testlab 6-17 © 2023 Siemens...
  • Page 42 TC20 Unit. Internal temperature sources are controlled by design in the TC20. Maximum power consumption in most demanding operating conditions 7 W. 6-18 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 43: Unit Features And Conditioning Options

    7. Unit features and conditioning options Supported functions of REC and DI Unit The tables below provide an overview of the supported functions of the Simcenter SCADAS RS Recorder unit (REC). Features Built-in intelligence On-board Simcenter SCADAS RS Recorder App ✓...
  • Page 44 TTL, HTL (single ended and differential), RS422/ ✓ ✓ RS485 Rotary or linear encoder sensors (ref, sense of ✓ ✓ rotation, pulse) Zero position based on reference pulse (for ✓ ✓ encoder type sensors) User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 45: Supported Functions Of Analog Signal Conditioning Units

    Supported functions of analog Signal Conditioning Units Supported functions of analog Signal Conditioning Units The tables below provide an overview of the supported functions of the Simcenter SCADAS RS Analog Signal Conditioning Units. Features U12-E Built-in intelligence On-board Simcenter SCADAS ✓...
  • Page 46 Other conditioning per Inductive AC LVDT/RVDT ✓ ✓ ✓ channel Potentiometers ✓ ✓ ✓ *) Requires external supply **) 5V unipolar is available from the 10 V bipolar supply User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 47 Common supply for all channels of the S24 unit: if the supply is activated on one channel, it will be present on all other channels, regardless of channel settings. User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 48: 8-Channel Thermocouple Type K Conditioning Unit

    The 8-Channel Thermocouple type K Conditioning Units (SC-TCK8-A and SC-TCK8-B) form a part of the already existing Siemens product portfolio. SC-TCK8 Units are external devices that allow extending the Simcenter SCADAS RS capability to acquire a high number of K-type thermocouples signals. They form a useful addition to the Simcenter SCADAS RS system.
  • Page 49 1 Simcenter SCADAS RS Recorder Unit 3 Terminator plug and TCK8 cables 2 SC-TCK8-A, SC-TCK8-B 4 Mating cable from Simcenter SCADAS RS to 2x DB9 connectors (available as Simcenter SCADAS RS accessory) User Manual Simcenter SCADAS RS system, Simcenter Testlab...
  • Page 50 7. Unit features and conditioning options User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 51: Mounting And Combining Units

    No. Description 1 Release button 2 Locking pin 3 Fixed alignment pins 4 Left: spring suspended alignment pins (bottom side of a unit) Right: holes (top side of a unit) User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 52: How To Stack Units

    2. Insert the spring suspended pins on the left side of the upper unit into the openings on the top of the lower unit. User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 53 Attention! • Siemens recommends stacking a maximum of 3 units to prevent instability and damage due to torque forces. • Stacking of more than 3 units is only allowed when using U-frame Supports...
  • Page 54: How To De-Stack Units

    How to de-stack units Step Visual 1. Depress the release button of the upper unit. 2. Keep the release button depressed and move the upper unit to the right. User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 55 How to de-stack units Step Visual 3. Lift the upper unit under a slight angle. 4. Move the upper unit to the left and detach it from the lower unit. User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 56 8. Mounting and combining units Step Visual 5. Lift the upper unit. User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 57: Back To Back Mounting

    Back to back mounting Back to back mounting Simcenter SCADAS RS units can be mounted back to back. In this case units are connected to each other by two U-frame Supports. The maximum number of units that can be mounted back to back with two U-frame Supports is two stacks of three units each.
  • Page 58 Do not over-tighten the bolts as it can damage the unit. The maximum applied torque is 6 Nm. ® Recommended thread-locker when required: Loctite 2400, medium-strength (refer to the TDS and MSDS for application and safety details). User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 59: Mounting Onto A Back Plate

    The depth of the threaded holes in the unit's rear side is 12 mm. To determine the maximum length of the bolt’s stem, add the thickness of the washers and the back plate to the depth of the threaded holes. User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 60 Do not over-tighten the bolts as it can damage the unit. The maximum applied torque is 6 Nm. ® Recommended thread-locker when required: Loctite 2400, medium-strength (refer to the TDS and MSDS for application and safety details). 8-10 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 61: Strapping Units

    Strapping units Strapping units In case the Simcenter SCADAS RS system is to be strapped down to a vehicle or other object, it can be equipped with Mounting Clamps and high-strength straps. To prevent damage to the test object and/or the RS system, the units must be strapped securely.
  • Page 62 (refer to the TDS and MSDS for application and safety details). Caution! Do not over-tighten the straps to prevent damaging the units. The straps must have a minimum tensile strength of 500 kg. 8-12 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 63: Configuring Units

    The Web App of the REC Unit can be used to configure the complete system and thereby each individual unit in the system. For stand-alone configuration units can be powered by means of a Siemens approved 48 VDC AC/DC power adapter.
  • Page 64 In case of problems refer to Solving common problems or contact your IT department. Attention! When a REC Unit is present, do not connect a PC to the daisy chain. User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 65: Connecting Cables

    It is allowed to use two or more UPS Units, because these units deliver power only "downstream" to subsequent units. Attention! Make sure that all unused connectors are sealed with a cap against dirt and moisture. User Manual Simcenter SCADAS RS system, Simcenter Testlab 10-1 © 2023 Siemens...
  • Page 66: Handling Sensor Plugs

    When connecting or disconnecting sensors from a unit, make sure to hold plugs by the ribbed part, NOT at the back nut. Yamaichi latching / de-latching mechanism is not operable from the back nut. 10-2 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 67: System Connectivity

    Host interface The Simcenter SCADAS RS Recorder Unit is at the heart of the system and can be accessed in different ways. The REC Unit can serve as a Wi-Fi access point, conform IEEE 802.11g and IEEE 802.11ac, that can serve a maximum of four clients.
  • Page 68: Synchronization Interface

    **) Although hardware is ready, it is not yet supported. Security Security of the environment in which the Simcenter SCADAS RS is used is a prerequisite for the safe use of equipment and protection of any data present in the system.
  • Page 69 To disassemble the system, do not remove daisy chain cables from the REC Unit until the system is switched off and its LED does not light up anymore. User Manual Simcenter SCADAS RS system, Simcenter Testlab 11-3 © 2023 Siemens...
  • Page 70 11. System connectivity 11-4 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 71: Operating Simcenter Scadas Rs

    The Uninterruptable Power Supply Unit is equipped with a built-in Li-Ion battery pack that serves as power buffer. Charge it before use with a Siemens approved AC/DC adapter or with the on-board power source of the vehicle or system under test.
  • Page 72: Before Powering Up

    Attention! • Simcenter SCADAS RS does NOT take ground from any power supply. • Electrical contact between units' chassis in a stack is provided by the short daisy chain cables, and NOT by the stack mechanism itself.
  • Page 73: On/Off Switching

    OFF automatically, by the "main" UPS state. If one of the secondary UPS goes OFF, i.e. by lack of available power, only downstream units will be switched OFF. User Manual Simcenter SCADAS RS system, Simcenter Testlab 12-3 © 2023 Siemens...
  • Page 74: Remote On/Off Switching

    • Using an external voltage source (6.5 V..60 V) • Between pins On/Off (1) and GND (2) • ON: If there is a voltage source • OFF: Otherwise 12-4 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 75 Goes low < 4.5 V SHUTDOWN SHUTDOWN SHUTDOWN VOLTAGE SWITCH Closed SHUTDOWN SHUTDOWN Opened SHUTDOWN ‒   ‒   NOTE: SHUTDOWN means gracefully shutting down. NOTE: Tolerance in voltage values is ± 10%. User Manual Simcenter SCADAS RS system, Simcenter Testlab 12-5 © 2023 Siemens...
  • Page 76: General Operational Considerations

    Warning! Do NOT connect the daisy chain to more than one power source such as a UPS Unit and a Siemens approved AC/DC adapter or two Siemens approved AC/DC adapters. This may cause damage to the units. It is allowed to use two or more UPS Units, because these units deliver power only "downstream"...
  • Page 77: Li-Ion Battery Safety Precautions

    It is recommended to switch off the power before connecting or disconnecting sensors. Attention! After using the Simcenter SCADAS RS system, shut off the power first, then disconnect the cables. Put a cap on the connector after disconnecting each cable before cleaning the units.
  • Page 78: Guidelines For Aerial Transport Of Batteries

    • Aggressive chemicals such as perchlorate, sulfuric acid, lye, in general chemicals with a pH value lower than 4 or higher than 9. • Heat sources. Do not open units. Replacement of the battery is to be performed by authorized Siemens personnel only. Guidelines for aerial transport of batteries According to the register of Dangerous Goods in the DGR, Lithium-ion batteries are classified in Class 9 –...
  • Page 79: Led Indications

    Normal White Upgrading firmware Normal Cyan Identification (via GUI) Fast Magenta *) Internal Error / Unexpected Error Solid Idle state Slow Green *) 5 s default, user editable. User Manual Simcenter SCADAS RS system, Simcenter Testlab 12-9 © 2023 Siemens...
  • Page 80: Ups Unit Leds

    DC power is present, no battery is being charged (high load, or over- Solid Cyan temperature, or battery failure) Switching on or shutting down because of power overload, over- Fast temperature, battery too low, or general error 12-10 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 81 DC power and external Battery Unit is detected and charging Normal Green DC power and external Battery Unit is detected and battery error Fast Green *) Future use. User Manual Simcenter SCADAS RS system, Simcenter Testlab 12-11 © 2023 Siemens...
  • Page 82: Conditioning Units Status Led

    Waiting for wake up Slow Green Busy (stopping recording, closing files, shutting down, synchronizing, etc.) Fast Yellow Data storage almost full Fast Throughput exceeded in one or more daisy chains Normal 12-12 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 83: Di Unit Status Leds

    Slave state Error LED Slave state INIT No error Blinking PRE-OPERATIONAL Blinking Invalid configuration Single Flash SAFE-OPERATIONAL Single flash Local error OPERATIONAL Double flash Watchdog timeout Application controller failure User Manual Simcenter SCADAS RS system, Simcenter Testlab 12-13 © 2023 Siemens...
  • Page 84: Shaping Filters

    In-band alias attenuation and overshoot characteristics of these filters are shown in the figure on the opposite page. Attention! Plot valid for any selectable sample rate different than the maximum. At maximum sample rate, in-band alias rejection is better than –110 dB. 12-14 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 85 Shaping filters User Manual Simcenter SCADAS RS system, Simcenter Testlab 12-15 © 2023 Siemens...
  • Page 86 12. Operating Simcenter SCADAS RS 12-16 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 87: Pin-Out & Wiring

    TEDS II *) Bridge – strain gage B24-120 Bridge – RTD B24-350 Potentiometer AC LVDT/RDVT Differential Current loop (externally supplied) TEDS II *) Chassis (female): YCP-TIA09BCG-09FPCY-18708 Plug (male): YCP-TPR09BCX-09MSCBX-051X User Manual Simcenter SCADAS RS system, Simcenter Testlab 13-1 © 2023 Siemens...
  • Page 88 The S24 Unit has a common supply for all channels: if the supply is activated on one channel, it will be present on all other channels, regardless of channel settings. 13-2 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 89: Digital Channels Pin-Out

    Chassis (female): YCP-TIA15FCG-10FPGZX-000X Plug (male): YCP-TPR15FCX-10MSGEX-076X CAN bus Chassis (female): YCP-TIA15ACG-06FPKZX-000X Plug (male): YCP-TPR15ACX-06MSKFX-061X Digital I/O – TTL – UART / RS-232 Chassis (female): YCP-TIA15BCG-10FPGZX-000X Plug (male): YCP-TPR15BCX-10MSGEX-076X User Manual Simcenter SCADAS RS system, Simcenter Testlab 13-3 © 2023 Siemens...
  • Page 90: Connecting Sensors

    The part shown in gray blue is within the unit. Analog sensor Wiring / Unit(s) Full bridge 6-wire (sense lines) Full bridge (4 wire) Half bridge 5-wire (sense lines) Half bridge 3-wire 13-4 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 91 Wiring Analog sensor Wiring / Unit(s) Quarter bridge 4-wire (sense line) Quarter bridge 3-wire Quarter bridge 2-wire This bridge configuration is not recommended Potentiometer (sense lines) Potentiometer User Manual Simcenter SCADAS RS system, Simcenter Testlab 13-5 © 2023 Siemens...
  • Page 92 Current loop 4-20 mA Using mating cable with included shunt Differential (with unipolar supply) B24: VSupply– pin is also active. If accidentally shorted, positive supply pin will also be disabled. 13-6 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 93 Wiring Analog sensor Wiring / Unit(s) Differential (with bipolar supply) Differential (external supply) ® (TEDS class I support) Single ended (with supply) Single ended (external supply) User Manual Simcenter SCADAS RS system, Simcenter Testlab 13-7 © 2023 Siemens...
  • Page 94 Single ended (external supply) using differential input Single ended (no supply – inductive) using differential input *) Although hardware is ready for TEDS, it is not yet supported. 13-8 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 95 7 & 8 Single ended incremental encoder (with ref. pulse) with supply) If the sensor does not provide a reference pulse, pin 4 may be left unconnected User Manual Simcenter SCADAS RS system, Simcenter Testlab 13-9 © 2023 Siemens...
  • Page 96 Make sure that all unused connectors are sealed with a cap to prevent dirt and moisture entering. Caution! Make sure that all plugs and cables are heat-resistant to at least +65 °C to prevent damage. 13-10 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 97: Wiring Notes

    The part shown in gray blue is within the unit. Wiring notes / Unit(s) Internal shunt (with sense lines) Internal shunt TEDS class II *) *) Although hardware is ready for TEDS, it is not yet supported. User Manual Simcenter SCADAS RS system, Simcenter Testlab 13-11 © 2023 Siemens...
  • Page 98 13. Pin-out & wiring 13-12 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 99: Maintenance And Calibration

    14. Maintenance and calibration Cleaning There is little maintenance to be performed on Simcenter SCADAS RS units. There are no user serviceable parts inside. It is important to remove any dirt or grease from the outside of the units. Cleaning of units on a vehicle...
  • Page 100: Calibration

    • Wipe the units dry with a lint-free cloth. Calibration Simcenter SCADAS RS signal conditioning units are factory calibrated and are accompanied by a calibration report. We recommend having your Simcenter SCADAS RS equipment calibrated on a yearly basis by our Customer Support team through either a maintenance or calibration contract.
  • Page 101: Software

    Full information can be found in the SCADAS RS Recorder App documentation. Firmware updates When new firmware is available, it must be uploaded to the REC Unit using the Simcenter SCADAS RS Recorder App, using the SCRSA-CABN02 (REC to PC) cable accessory.
  • Page 102 15. Software 15-2 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 103: Troubleshooting

    Windows PC your local IT department Samba server is not discovered by "\\A.B.C.D" in the windows WSDDiscovery search box, where A.B.C.D is the REC Unit HOST port IP address. User Manual Simcenter SCADAS RS system, Simcenter Testlab 16-1 © 2023 Siemens...
  • Page 104 Reset to factory defaults will bring the IP setting to defaults. Conflicting names No unique name configured for a Rename device/SSID Wi-Fi access point Don't know which device is connected 16-2 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 105: Glossary

    CAN with Flexible Data-Rate An extension to the original CAN bus protocol that yields more accurate, "real-time" data CCP microphone Constant Current Power Special type of microphone for measuring microphone purposes User Manual Simcenter SCADAS RS system, Simcenter Testlab 17-1 © 2023 Siemens...
  • Page 106 EtherCAT Ethernet for Control An Ethernet-based fieldbus system, suitable Automation Technology for both hard and soft real-time computing requirements in automation technology 17-2 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 107 An instrument that can integrate the movements of a moving object to estimate its orientation, its linear velocity and its position IPAC Internet Protocol Automatic See APIPA Configuration User Manual Simcenter SCADAS RS system, Simcenter Testlab 17-3 © 2023 Siemens...
  • Page 108 Noise, Vibration, Harshness Main application fields for SCADAS On-Board Diagnostics A term referring to the vehicle management system and the interface for reading information of different parts of the vehicle 17-4 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 109 A the gender of the interface Resistance Temperature Device that determines the temperature by Device / Resistance measuring the resistance of a pure electrical wire Temperature Sensor User Manual Simcenter SCADAS RS system, Simcenter Testlab 17-5 © 2023 Siemens...
  • Page 110 Ultra DMA, Ultra Direct Fast interface to transfer data Memory Access UpnP Universal Plug and Play A collection of computer protocols that allow devices to be connected wirelessly 17-6 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 111 (LAN) within a limited area Universal Measurement and A network protocol for connecting calibration Calibration Protocol systems to electronic control units (ECUs) User Manual Simcenter SCADAS RS system, Simcenter Testlab 17-7 © 2023 Siemens...
  • Page 112 17. Glossary 17-8 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 113: Product Compliance

    18. Product compliance Europe Simcenter SCADAS RS products SCRS-UPS, SCRS-REC, SCRS-DI, SCRS-S24, SCRS-B24-120, SCRS-B24- 350, SCRS-U12, SCRS-U12-E, SCRS-ECAT and SCRS-TC20 comply with the following European directives: • 2014/35/EU – Low Voltage Directive (LVD) on health and safety risks of electrical and electronic equipment •...
  • Page 114: Fcc Compatibility

    However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television 18-2 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 115: Safety Labels

    On the bottom of the unit Attention! Read the User Manual before using this equipment; it gives important safety information On the bottom of the unit WEEE conformity User Manual Simcenter SCADAS RS system, Simcenter Testlab 18-3 © 2023 Siemens...
  • Page 116 18. Product compliance 18-4 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 117 When the product has reached its end of life, dispose of it according to local rules and regulations. Do NOT throw any piece or part in with normal waste. Recycle any piece or part that can be recycled. User Manual Simcenter SCADAS RS system, Simcenter Testlab 19-1 © 2023 Siemens...
  • Page 118 19. End of life and Disposal 19-2 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...
  • Page 119 ..........User Manual Simcenter SCADAS RS system, Simcenter Testlab 20-1 ©...
  • Page 120 ..........20-2 User Manual Simcenter SCADAS RS system, Simcenter Testlab © 2023 Siemens...

Table of Contents