Starting/ending for synchronous control

Set the advanced synchronous control parameters for each output axis to start synchronous control.
The status changes to synchronous control after the advanced synchronous control parameters are analyzed at the start of
synchronous control, and the output axes synchronize with input axis operations.
[Cd.380] Synchronous control start
(Target axis bit)
[Md.141] BUSY
(Target axis bit)
[Md.26] Axis operation status
[Md.321] Synchronous encoder
axis position value
per cycle
[Md.407] Cam axis position
value per cycle
[Md.20] Command position
value
Synchronous control system control data
Setting item
Setting details
[Cd.380]
• Synchronous control begins if the target axis bit
Synchronous
is turned ON.
control start
• Synchronous control ends if the bit is turned
OFF during synchronous control.
Fetch cycle: Operation cycle
*1 When the synchronous control analysis mode is executed simultaneously or the synchronous control analysis mode and the
synchronous control start are executed simultaneously for multiple axes, perform the setting for the synchronous control start in batches
for each word. If the axes are set continuously in bits, the synchronous control analysis mode and the synchronous control start may not
operate depending on the timing.
*2 The range from axis 1 to 4 is valid in the 4-axis module and from axis 1 to 8 is valid in the 8-axis module.
Starting method for synchronous control
Synchronous control can be started by turning the target axis bit from OFF to ON in "[Cd.380] Synchronous control start" after
setting the advanced synchronous control parameters.
"5: Analyzing" is set in "[Md.26] Axis operation status" at the synchronous control start, and the advanced synchronous control
parameters are analyzed. "[Md.141] BUSY" turns ON after completion of analysis, and "15: Synchronous control" is set in
"[Md.26] Axis operation status".
Start the input axis operation after confirming that "15: Synchronous control" is set in "[Md.26] Axis operation status".
Ending method for synchronous control
Synchronous control can be ended by turning the target axis bit from ON to OFF in "[Cd.380] Synchronous control start" after
the input axis operation is stopped.
"[Md.141] BUSY" turns OFF at the synchronous control end, and "0: Standby" is set in "[Md.26] Axis operation status" at the
output axis stop.
Synchronous control can also be ended by turning the target axis bit from ON to OFF in "[Cd.380] Synchronous control start"
during the input axis operation. However, it is recommended to end after stopping the input axis operation since the output
axis stops immediately.
Refer to the following for the stop operation of output axis at the synchronous control end.
Page 26 Stop operation of output axis
1 OUTLINE OF ADVANCED SYNCHRONOUS CONTROL
24
1.3 Operation Method of Synchronous Control
Standby (0)
Analyzing (5)
Synchronous control (15)
Setting value
*1
■Set the target axis in bits.
*2
(bit0: axis 1 to bit7: axis 8
)
OFF: Synchronous control end
ON: Synchronous control start
Standby (0)
t
t
t
Default value
Buffer memory
address
0
36320