Command Generation Axis Parameters - Mitsubishi Electric MELSEC iQ-F FX5 Series User Manual

Motion module/ simple motion module
Hide thumbs Also See for MELSEC iQ-F FX5 Series:
Table of Contents

Advertisement

Command generation axis parameters

All command generation axis parameters are prepared for each command generation axis. However, change the parameters
using GX Works3 or control data because the parameters are not in the buffer memory.
Setting item
[Pr.340]
Command generation axis valid
setting
[Pr.346]
Command generation axis length per
cycle
*1 Command generation axis position units (Page 38 Command generation axis position units)
[Pr.340] Command generation axis valid setting
Set valid/invalid of the command generation axis.
Setting value
0: Invalid
1: Valid
[Pr.346] Command generation axis length per cycle
Set the length per cycle for the command generation axis position value per cycle.
The current value of command generation axis is stored in "[Md.347] Command generation axis position value per cycle" at
ring counter based on the setting value.
The unit settings are in command generation axis position units (Page 38 Command generation axis position units).
Set a value within the range from 1 to 2147483647. If a value out of the range is input, the axis error "Outside command
generation axis length per cycle setting error" (error code: 1BADH [FX5-SSC-S], or error code: 1DFDH [FX5-SSC-G]) occurs
and the axis operates as that the length per cycle is 0.
If "0" is set, "[Md.347] Command generation axis position value per cycle" is not updated.
Setting details
Set valid/invalid of the command
generation axis to be used.
Fetch cycle: At power supply ON
Set the length per cycle of the
command generation axis.
Fetch cycle: At power supply ON
Details
Command generation axis is invalid.
Command generation axis is valid.
Setting value
■Set in decimal.
0: Invalid
1: Valid
■Set in decimal.
0: Invalid
1 to 2147483647
[Command generation axis position
*1
units
]
2.2 Command Generation Axis
Default value
Buffer memory
address
0
0
2 INPUT AXIS MODULE