[Pr.430] Slippage amount at auxiliary shaft clutch ON
Set the slippage amount at clutch ON when the slippage method is set in "[Pr.428] Auxiliary shaft clutch smoothing method".
The slippage amount is set in units based on the current value selected in "[Pr.423] Auxiliary shaft clutch reference address
setting".
If the set amount is negative, the slippage amount at clutch ON is controlled as 0 (direct).
[Pr.431] Slippage amount at auxiliary shaft clutch OFF
Set the slippage amount at clutch OFF when the slippage method is set in "[Pr.428] Auxiliary shaft clutch smoothing method".
The slippage amount is set in units based on the current value selected in "[Pr.423] Auxiliary shaft clutch reference address
setting".
If the set amount is negative, the slippage amount at clutch OFF is controlled as 0 (direct).
4 ADVANCED SYNCHRONOUS CONTROL