Mitsubishi Electric MELSEC iQ-F FX5 Series User Manual page 97

Motion module/ simple motion module
Hide thumbs Also See for MELSEC iQ-F FX5 Series:
Table of Contents

Advertisement

[Cd.608] Cam auto-generation request
Set "1: Cam auto-generation request" to execute cam auto-generation.
Cam data is generated in the cam open area of the specified cam No. based on the cam auto-generation data.
The setting value is reset to "0" automatically after completing the process.
The cam auto-generation data is saved in the cam storage area. The cam auto-generation is executed automatically again
when the next power supply turns ON or "[Cd.190] PLC READY signal" OFF to ON.
If a warning occurs when requesting cam auto-generation, the warning No. is stored in "[Md.24] Axis warning No." of axis 1,
and the setting value is reset to "0" automatically.
3
When another request command is set, this function does not get executed and the setting value is reset to "0" automatically.
[Cd.609] Cam auto-generation cam No.
Set the cam No. to be generated automatically.
[Cd.610] Cam auto-generation type
Set the type of cam auto-generation.
3 CAM FUNCTION
95
3.2 Create Cam Data