17000 - CO2 Laser Tube Replacement
CO2 Laser Tube
Replacement
CO2 Laser Tube Removal
1. Turn off the engraver.
2. Disconnect engraver from power.
3. Depending on the model of engraver,
remove the back or lower rear panel of
the engraver to uncover the laser bay:
4. Disconnect the red dot pointer harness
on the right side of the laser tube:
5. Disconnect the data cable on the left
side of the laser tube:
6. Disconnect the laser tube power
harness from the main electrical
harness of the engraver.
Do not remove the power harness from the
laser tube. This should remain
connected to the laser tube when being
sent back to the factory. The
replacement laser tube will arrive with a
replacement power harness attached.
7. Loosen the three (3) green-capped
Phillips captive screws on the laser tube
mounting brackets. There is one (1) on
the left bracket and two (2) on the right
bracket: