17000 - Z-Axis PCB Replacement
Z-Axis PCB Replacement
Z-Axis PCB Removal
1. Turn off the engraver.
2. Disconnect the engraver from power.
3. Remove the right panel of the
engraver:
4. Place the anti-static strap around
your wrist and attach the clamp to a
bare metal surface on the engraver.
5. Locate the Z-axis PCB at the front right
side of the engraver:
!
5. Using a pencil, make a mark on the
engraver chassis that corresponds
with the top edge of the z-axis PCB.
This will help to ensure that the new
z-axis PCB is installed in the correct
position:
6. Disconnect the data cable on the
z-axis PCB: