VPL400-X: SECTION 8
MAINTENANCE
SECTION 8
MAINTENANCE & INSPECTION
Annual inspections are required to help prevent
unsafe conditions and operation.

RESIDENTIAL APPLICATIONS

OWNER / MAINTENANCE PERSONAL
BEFORE USE
Do not use lift until these conditions are rectified.
All doors and gates are locked and secure.
Ensure there is no standing water around the
unit.
Make sure the AC connections are in good
condition and that there are no cracks or gaps
in conduit.
Make sure there are no obstructions intruding
in the path of the lift.
People, tree branches, loose items, etc.
Check that there is no loose hardware or
emerging cracks/deformations in the platform
and tower. Make sure that there are no unusual
noise or vibrations that develop.
PERIODICALLY
Check and ensure that the safety pan under
the platform moves freely up and down and is
not damaged. This is the built-in safety device
designed to detect obstructions under the
platform and stop platform downward motion. If
for any reason the safety pan does not move as
intended, please contact your dealer.
Check and ensure that all labels are intact and
legible. If any safety or warning labels need to
be replaced, please contact your dealer.
Make sure you have a copy of the Owner's
Manual. A digital copy of the Owner's Manual is
available at harmar.com.
VPL400-X:
Install Manual
36
21JULY2023 | 630-00159 B
Check your key locks and emergency
stop button for functionality. Ensure user
understands overrides and understands how
to manually open the gate in the event of an
emergency.
EMERGENCY GATE KEY MUST BE
LEFT WITH END USER.
Check for any rust that may be developing.
Rust is expected in outdoor applications
(especially in coastal areas), but with proactive
maintenance or quick repair, this can be
minimized.
IMPORTANT
Understanding State/Local Inspection Requirements
and Timing - Always Required.

MAINTENANCE SCHEDULE

RECOMMENDED EVERY 6-MONTHS
NOTICE
We recommend this be performed by a qualified
service technician.
Check for motor gearbox leaks
Check wear pads for gaps
Lubricate ACME screw with Nook PAG-1 ACME
Screw Grease
Check all structural connections/hardware
Inspect the safety brake
Ensure the electrical disconnect works as
intended
Check all interlocks, and obstruction sensors