The function RESTORE PARAM allows transfer of data stored in the console memory
to the controller in the same way of the model loaded with the function SAVE PARAM.
Data loaded in the controller by means of the function RESTORE PARAM. is:
- all the parameters values (PARAMETERS CHANGE);
- the settings of the option (SET. OPTION);
- the setting of the battery (ADJUST BATTERY).
ATTENTION:
How to enter in the RESTORE function by the console:
1) Opening display.
2) Press ENTER to enter the main menu.
3) The first item of the list appears.
4) Scroll the list with the buttons ROLL UP or ROLL DOWN.
Select RESTORE PARAM.
5) The selected item (RESTORE PARAM.) appears.
6) Press ENTER to enter the function RESTORE PARAM.
7) In the first line the model code selected appears
and in the second line the type of controller stored
in the memory appears.
8) Select the model code with the buttons ROLL UP
and ROLL DOWN.
9) The model code selected and the type
of controller stored appears.
10) Press ENTER to confirm the loading operation.
11) The confirmation request for the operation appears
(ENTER = YES, OUT = NO).
12) Press ENTER to confirm the loading operation
(OUT for cancelling).
13) The list of the parameter items during the
loading phase appears.
14) At the end of the operation it returns to the
main menu RESTORE PARAM.
Page 30

6.4 RESTORE PARAMETERS: DESCRIPTION

the function RESTORE overwrites all the data of the controller.
After this operation, old configuration data is cancelled.