Using the CONFIG MENU of the programming console, the user can configure the
following functions:
SUBMENU "SET OPTIONS":
1. HOUR COUNTER:
- RUNNING:
- KEYON:
2. BATTERY CHECK:
- ON:
- OFF:
3. QUICK INVERSION:
- FREE:
- HANDLE:
4. CURVE BRAKING:
- ON:
- OFF:
5. SAFETY SWITCH:
- NONE:
- HANDLE:
- SEAT:
6. DIR. SELECTOR:
- NONE:
- PRESENT:
7. ANTI ROLL-BACK:
- ON:
- OFF:
8. TRANSPALLET MODE:
- ON:
- OFF:
5 CONFIGURATION FUNCTION
the hour counter is active only when running.
the hour counter is active when the key is ON.
the battery charge is continuosly monitored .
the battery test is not carried out.
the IR is active in standby, it has no timeout and finishes
only when the operator switches all the input signals off;
the IR finishes after a timeout; the chopper starts again
only when the operator switches all the input signals off.
when the RV1 is held ACTIVE during running, the new
speed is reached by braking with an intensity established
by the CURVE BRAKING parameter (see 4.2).
the new speed is reached with a deceleration whose
intensity is established by the SPEED LIMIT BRAKING
parameter (see 5.2).
the safety switch is not present.
a tiller is present.
a seat switch is present.
double pedal (one for forward direction, the other one for
backward direction).
running selector + single pedal.
when left on a ramp without a running request the ma-
chine does not roll-down.
this function is not activated.
in this mode the acceleration and braking ramps are faster
(twice).
standard ramps (switched for golf-car).
SEM1
Page 17
Need help?
Do you have a question about the SEM1 and is the answer not in the manual?
Questions and answers