Ulvac CRYOPUMP CRYO-U Series Instruction Manual page 65

Hide thumbs Also See for CRYOPUMP CRYO-U Series:
Table of Contents

Advertisement

Maintenance
S: Scheduled maintenance
Item
Cryopump
U
80K baffle
U
15K cryopanel
replacement
U
Cryopump cleaning
S Insulation properties of
heater for regeneration
(*1)
S Pressure relief valve
U Calibration of cryometer
Refrigerator unit
S
Seal kit replacement
S
Driver assembly
Replacement
S
Motor bearing replacement
S
Cylinder bolt replacement
S Displacer replacement
S Valve body replacement
U Other parts replacement
Compressor unit
S Adsorber replacement
(*1): Only applicable to a cryopump system with heater.
8-2
Table 8-1 Maintenance Parts and Intervals
U: Unscheduled maintenance or part replacement at fault
Parts
15K cryopanel
Heater
Pressure
relief valve
MBS-C
Cryometer
Seal kit
Driver bearing
Valve bearing
Set screw
Motor bearing
cylinder bolt
st
nd
1
/2
stage of
displacer
Intake/Exhaust
valve body
Other parts
Adsorber
Refer to the compressor unit instruction manual.
ULVAC CRYOGENICS INCORPORATED
Interval
At fault
Every month
Once or twice a month
At fault
R50
RM50
R50R
RM50T
R50RT
12,000h
16,000h
12,000h
16,000h
12,000h
16,000h
At fault
Remarks
When
reassembling,
be sure to use new
indium
gasket.
Replace when
10MΩ or less
Confirm the
safety of
exhaust gas
Use
the
(paid)
calibration service.
The maintenance
cycle depends on
the manner of
operation.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cryopump cryo-u 18h

Table of Contents