Commissioning and Configuration
A detected alarm is like a direct call button (alarm key) that has been pressed, and a call number
can be defined via configuration step 18 which will be called when the alarm key is pressed, i.e.
when an alarm is detected. If an alarm is detected, this setting can be used to specify how exactly it
is handled, like a key or like a message.
Treat like a key
If the device is at rest and an alarm is detected, the set action is triggered. If, on the other hand, the
device is connected and an alarm is detected, then it is treated like a keystroke. If breaking the con-
nection is allowed, the connection is terminated and the action set for the alarm input is triggered.
If breaking the connection and performing another action is not allowed, the function set for the
alarm input will not be performed, so the alarm will be lost.
Treat like a message
If the device is at rest and an alarm is detected, the set action is triggered. If, on the other hand, the
device is connected and an alarm is detected, it will be saved and the set action will be triggered as
soon as the connection is terminated and the device is at rest again.
Call number configuration
Call numbers consist of digits only and may be up to 50 digits long.
Call number for the alarm input
18
Call number #
Here you can define the call number that will be called when an alarm is detected
.