4.3. Problem after configuration change
If the device no longer starts correctly due to
incorrect configuration, it should be reset to
factory settings as follows.
Disconnect the device from the power
supply (Network cable / PoE injector)
Wait briefly and then reconnect the
power supply
Immediately press the configuration
key and hold before status LED lights
up
Status LED lights up red
Keep holding the configuration key
for at least 5 seconds
Status LED lights up white
Immediately release the configuration
key and then press 2 times briefly
Device starts and resets the configura
tion to factory settings
www.behnke-online.de
Commissioning and Configuration
4.4. Hardware error
If there is a hardware error, the device tries out
an error number via the status LED, the loud-
speaker or the display, if this is still possible
and any of these are available.
2 Initialization error
3 IO error
4 Network hardware error
5 Network adapter error
6 Audio adapter error
7 Line adapter error
8 USB hardware error
9 AIF error
10 no detached electronics detected
The error number is displayed via the status LED
as follows.
Status LED lights up red
for about 20 seconds
Status LED briefly goes off
Status LED flashes yellow several times
:
to display the error number
Device restarts
In case of a hardware failure, please contact our
service call hotline: