Figure 2: Optimizing detection and avoiding false alarms
1. Do not install near high-voltage electrical lines.
2. Keep away from heat sources.
3. Do not install outdoors.
4. Avoid direct sunlight.
5. Do not expose to air drafts.
6. Do not install behind partitions.
7. Do not mount on an unstable surface.
8. Install on a solid and stable surface at a height of 1.8 m to 2.4 m (6 ft. to 8 ft.).
WARNING: Do not obscure partially or completely the detector's field of view.
Enrolling the device
1.
Refer to the control panel installation manual for the complete set of enrollment instructions
and testing procedures.
2.
From the Installation menu, enter the Device enrollment menu and select the option to add
a new device.
3.
Remove the battery pull-tab to power on the device and begin the auto-enrollment process.
If the battery pull-tab is not available or if the device does not automatically enroll, open the
device cover to trigger the enrollment. Alternatively, press the enroll button until the orange
LED light turns on. See
4.
If requested, enter the PIN code printed on the device label.
5.
To manually enroll the device:
a. Scan the QR Code on the device box, using the IQ4 camera if available, or see step b.
b. Manually enter the device ID, printed on the product label, in the format ID:145-xxxx.
Note: If the device has been powered up for more than 48 hours it will be identified by
the system only after the device has been reset.
The NEXT CAM PG+ is enrolled with device ID 145-XXXX. In fall back mode it enrolls as NEXT
CAM PG2 with device ID 140-XXXX.
6.
Select the desired zone.
7.
Configure any device parameters that are required.
8.
Mount and test the device. See
2
NEXT CAM PG+ Motion Detector with Integrated Camera Installation Guide
Figure
1.
Local diagnostics test
D-308840 NEXT CAM PG+ Rev. 0
for information on testing the device.