Gas flow rate and
Inspection equipment: Test box "torch flow rate" (4,078,016)
leak test/PP-
SER-2001
The "gas flow rate" limit values can be
found in the "PP-SER-2001" test schedule.
Check the hosepack for flow rate.
Straighten the hosepack with the
1
attached torch body and place it down
Insert flow tester as shown and start
2
gas flow
Compare values according to torch
3
type and test schedule
Check the hosepack for leaks.
Test the hosepack with attached torch
1
body without consumables
Insert flow tester as shown in previous
2
image and start gas flow
Seal the torch body and check the
3
hosepack for leaks
57