Removing, repla-
1
cing, and fitting
the hosepack
4
50
(2)
(1)
Pull out all components from the central connector end
(1)
(4) (5)
(3)
(2)
(1)
(3)
(2)
Pull all components in from the central connector end, taking into account the corres-
ponding cable and hose length distances (see the following overviews)
Remove the insert pieces (1)
3
Feed out the control line (2)
4
Water-cooled version only:
Thread out the water flow hose (3)
5
and the water return hose (4) in front
of the control line
(4)
(3)
Disassemble the components to be
2
replaced on the central connector:
-
Remove the power cable (1)
-
Open clamp 7 (2) on the gas hose
and pull off the gas hose (3)
ATTENTION! ?
If necessary, the water return hose (4)
can be replaced. For the hose length,
see the following overviews. The water
return hose is mounted on the central
connector with a clamp 9 (5). The water
connection at the other end of the hose
is mounted with a clamp 10.
Prepare replacement components in
3
accordance with the corresponding
cable and hose lengths (see the fol-
lowing overviews) and mount them on
the central connector:
-
Connect the power cable (1)
-
Connect the gas hose (3) and
secure it with clamp 7 (2)