Replace The Lip Seal On The Flue Outlet - Worcester Greenstar 1000 GR1000W 24 C NG Installation And Maintenance Instructions Manual

Gas-fired condensing combi appliance
Table of Contents

Advertisement

Assemble the NTC on the return pipe
1
2
Fig. 163 Assemble the new NTC on the return pipe
[1]
Ignition transformer
[2]
NTC
[3]
Auto air vent
▶ Place the new NTC [2] on the flat surface of the return pipe (close to
the inlet of the heat exchanger) (position  Chapter 9.11, page 59).
▶ Connect the cable to the new NTC.
▶ Connect the cables to the ignition transformer [1].
▶ Rotate the auto air vent [3] to the initial position.
Fig. 164 Auto air vent position
▶ Adjust the position of the auto air vent. It must be aligned at an angle
of approximately 90 degree to the bottom plate.
Greenstar 1000 – 6721835943 (2023/08)
3
0010046044-001
0010046045-001
Disassemble the NTC from the flow pipe
1
2
Fig. 165 Replace the NTC at the flow pipe
[1]
Gas hose
[2]
NTC
▶ Take out the gas hose [1] ( Chapter 10.9, page 68).
▶ Remove the connector sockets [2] from the NTC on the flow pipe.
▶ Remove the NTC from the flow pipe.
Assemble the NTC on the flow pipe
▶ Place the new NTC [2] on the flat surface of the flow pipe (close to the
inlet of the heat exchanger) ( Figure 165) (position
 Chapter 9.11, page 59).
▶ Connect the cable to the new NTC.
▶ Assemble the gas hose ( Chapter 10.9, page 68).

10.22 Replace the lip seal on the flue outlet

Disassemble the lip seal
1
2
3
Fig. 166 Disassembly of the flue adaptor and the flue kit
[1]
Screws
[2]
Flue adaptor/flue kit
[3]
Lip seal
▶ Remove three screws (pozi or hexagon) [1] from the flue adaptor and
the flue kit [2].
▶ Take out the flue adaptor and the flue kit to reach the lip seal.
▶ Remove the lip seal from the flue outlet.
Replacement parts
0010046046-001
0010046051-001
79

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greenstar 1000 gr1000w 30 c ng

Table of Contents