Replace The Temperature Limiter - Worcester Greenstar 1000 GR1000W 24 C NG Installation And Maintenance Instructions Manual

Gas-fired condensing combi appliance
Table of Contents

Advertisement

Replacement parts
2.
1.
Fig. 126 Assembly of the screws and nut
▶ Tighten two screws on the gas valve to fix it.
▶ Tighten the gas valve nut.
1
Fig. 127 Assembly of the gas hose
[1]
Gas hose
▶ Push the gas hose [1] to the restrictor on the gas valve.
▶ Match the guide feature with the gas valve.
▶ Reconnect the cable to the gas valve.
70
0010045922-001
1
0010045926-001

10.12 Replace the temperature limiter

2.
2
1
1.
Fig. 128 Disassembly of the temperature limiter
[1]
Cable sockets
[2]
Temperature limiter
▶ Disconnect the cable sockets [1] from the temperature limiter.
▶ Loosen the temperature limiter [2] in counter-clockwise direction by
a 16 mm hexagon wrench.
1.
2
1
2.
Fig. 129 Assembly of the temperature limiter
[1]
Cable sockets
[2]
Temperature limiter
▶ Tighten the temperature limiter [2] in clockwise direction with a
16 mm hexagon wrench.
▶ Connect the cable sockets [1] to the temperature limiter.
Greenstar 1000 – 6721835943 (2023/08)
0010045927-002
0010045928-002