Product clearances:
▶ Minimum clearances must be maintained around the product.
7
6
5
Fig. 42 Roof space installation clearances
[1]
Product
[2]
Clearance below
[3]
Side clearance
[4]
Front clearance
[5]
Permanently fixed, retractable loft ladder
[6]
Safety guard, handrail or safety chain
[7]
Fixed lighting
Minimum clearances
Description
2
Below the product to the loft floor boarding
3
Either side of product to the edge of the loft
floor boarding
4
In front of product to the loft floor boarding
or the loft hatch
1) The shortest distance must be applied. If the work area does not extend to the loft
hatch, then there must be a safe walkway of at least 600mm wide to the boarded
work area.
Table 18 Minimum clearances
Before installing the appliance, ensure that the system has been cleaned
and a filter is fitted.
Greenstar 1000 – 6721835943 (2023/08)
1
2
3
3
4
0010051469-001
Dimensions (mm)
600
600
1,200
1)
5.1

Position the appliance

HRisk of explosion from escaping gas!
Escaping gas can cause an explosion.
▶ Ensure the mains gas supply is isolated before starting any work and
follow all relevant safety precautions.
NOTICE
Incorrect mounting can cause material damage.
If the appliance is mounted incorrectly, it may fall off the wall.
▶ Ensure the appliance is mounted onto a flat, fixed rigid surface
capable of supporting the appliance weight.
▶ Only use screws and rawl plugs that are suitable for the wall type and
weight of the appliance.
▶ Ensure all aspects of the installation are considered when positioning
the appliance, flue run and discharge, condensate disposal, PRV
discharge etc.
WARNING
Damage to property!
Damage caused by drilling into pipes, electrical cables, damp proof
course or other hazards.
▶ Before drilling ensure that there are no obstructions or other hazards.
NOTICE
Damage to appliance!
Residue, metal shavings, and contaminants in the system pipe work can
damage the appliance.
▶ Flush the system pipe work thoroughly to remove all residue.
▶ Follow the instructions with respect to cleaning primary systems.
Running pipes to the appliance.
• The area around a rear flue outlet must be avoided.
5.1.1

Mounting bracket fixing

Wall mounting template
▶ The wall mounting template has been sized to allow for the minimum
clearances around the appliance, ( section Fig. 11 "Appliance
minimum clearances").
Installation