Replace The Back Flow Prevention Valve - Worcester Greenstar 1000 GR1000W 24 C NG Installation And Maintenance Instructions Manual

Gas-fired condensing combi appliance
Table of Contents

Advertisement

10.8

Replace the back flow prevention valve

When replacing the back flow prevention valve, the correct assembly of
the burner door seal must be checked.
▶ Replace the burner door seal (Chapter 10.7, page 65).
2
1
Fig. 114 Remove the gas air pipe
[1]
Screws (TORX T20)
[2]
Gas air pipe
▶ Take out two screws (Torx T20) [1] to remove the gas air pipe [2].
1
1.
Fig. 115 Replace he back flow prevention valve
[1]
Old back flow prevention valve
[2]
Housing
[3]
New back flow prevention valve
▶ Remove the old back flow prevention valve [1].
▶ Place the housing [2] inside the new back flow prevention valve [3].
Greenstar 1000 – 6721835943 (2023/08)
Fig. 116 Position of the back flow prevention valve on the fan
[1]
▶ Put the back flow prevention valve [1] on the fan.
▶ Ensure that the back flow prevention valve [1] is properly located into
the fan.
0010045880-001
2
2.
Fig. 117 Assembly of the gas air pipe, the fan and the back flow
3
[1]
[2]
▶ Put the gas air pipe [2] on the back flow prevention valve and on the
0010045891-001
fan.
▶ Tighten the two screws [1] (Torx T20). Do not over-tighten.
1
1
Back flow prevention valve
2
1
prevention valve
Screws
Gas air pipe
Replacement parts
0010045893-001
0010045902-001
67