Worcester Greenstar 1000 GR1000W 24 C NG Installation And Maintenance Instructions Manual page 21

Gas-fired condensing combi appliance
Table of Contents

Advertisement

Vertical flue terminal positions
1
RIDGE VENT
RIDGE FLUE
1500
600
1500
BOUNDARY LINE
BOUNDARIES
1/2
1/2
Fig. 29 Vertical flue terminal positions
Key to figure 29:
[1]
1,500mm measured between a vertical flue terminal and an
opening or vented window. 500mm measured horizontally
between a vertical flue terminal and an opening or vented window
providing the flue terminal is at least 300mm above the opening.
[2]
Minimum clearance to an additional flue, 600mm to a room
sealed flue or 1,500mm to an open flue.
[3]
300mm clearance from a vertical flue terminal adjacent to a
boundary line, unless it will cause a nuisance. BS 5440: Part 1
recommends that care is taken when siting a terminal in relation to
boundary lines.
[4]
600mm minimum clearance measured from an opening or vented
skylight to a vertical flue terminal. If the terminal is within
1,500mm of the opening or vented skylight then it must be at
least 300mm above the opening.
[5]
500mm clearance measured horizontally from a vertical flue to a
vertical structure.
Not required if the terminal is 300mm above the structure.
[6]
The flue must not penetrate the roof in the shaded area.
The terminal must be at least 1,500mm from the opening or vent
when sited below the window or 600mm when sited to either side
or above.
Greenstar 1000 – 6721835943 (2023/08)
2
2
1500
8
1200
5
500
300
300
3
9
2
300
1500
600
7
400
300
10
4
1500
600
500
5
[7]
400mm measured diagonally from a pitched roof or 500mm in
regions with heavy snow fall. 300mm measured vertically from
the air intake to the closest intersection with the roof.
[8]
1,200mm separation measured between a vertical flue and a
horizontal flue terminal.
[9]
For the purpose of determining suitable flue terminal positions for
gas appliances, the boundary can be considered to extend to the
centre line of any adjacent routes or waterways e.g. paths,
streets, rights of way, canals, rivers or railways.
[10] 1,500mm measured between a vertical flue terminal and an
opening or vented window. 500mm measured horizontally
between a vertical flue terminal and an opening or vented window
providing the flue terminal is at least 300mm above the opening.
Note:
▶ Where a vertical flue terminates in an area that is enclosed on 3 sides,
the flue must be no more than 1,000mm below the lowest roof line.
You must ensure that all clearances are maintained and that products
of combustion disperse safely from the area.
Pre-Installation
600
600
600
1500
2000
7
400
500
5
6
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greenstar 1000 gr1000w 30 c ng

Table of Contents