Worcester Greenstar Ri User Instructions & Customer Care Manual

Worcester Greenstar Ri User Instructions & Customer Care Manual

Wall hung gas-fired boiler
Hide thumbs Also See for Greenstar Ri:

Advertisement

USER INSTRUCTIONS &
CUSTOMER CARE GUIDE
Greenstar Ri
WALL HUNG GAS-FIRED BOILER
FOR OPEN VENT & SEALED CENTRAL HEATING SYSTEMS & INDIRECT FED DOMESTIC HOT WATER
THIS BOILER IS USED WITH
NATURAL GAS OR LPG (Cat II 2H3P TYPE C13, C33 & C53)
NATURAL GAS
LIQUID PETROLEUM GAS
12 Ri GC NUMBER: 41 311 63
15 Ri GC NUMBER: 41 311 75
18 Ri GC NUMBER: 41 311 77
24 Ri GC NUMBER: 41 311 65
12 Ri GC NUMBER: 41 311 64
15 Ri GC NUMBER: 41 311 76
18 Ri GC NUMBER: 41 311 78
24 Ri GC NUMBER: 41 311 66

Advertisement

Table of Contents
loading

Summary of Contents for Worcester Greenstar Ri

  • Page 1: User Instructions

    USER INSTRUCTIONS & CUSTOMER CARE GUIDE Greenstar Ri WALL HUNG GAS-FIRED BOILER FOR OPEN VENT & SEALED CENTRAL HEATING SYSTEMS & INDIRECT FED DOMESTIC HOT WATER THIS BOILER IS USED WITH NATURAL GAS OR LPG (Cat II 2H3P TYPE C13, C33 & C53)
  • Page 2 TECHNICAL: 08705 266241 CAREFULLY BEFORE OPERATING SERVICE: 08457 256206 YOUR BOILER LITERATURE: 01905 752556 THESE INSTRUCTIONS ARE APPLICABLE TO THE WORCESTER, SALES: 01905 752640 BOSCH GROUP BOILER MODEL(S) WEBSITE: www.worcester-bosch.co.uk STATED ON THE FRONT COVER OF THIS MANUAL ONLY AND MUST NOT BE USED WITH ANY OTHER MAKE OR MODEL OF BOILER.
  • Page 3: Table Of Contents

    There is also the reassurance of our no-nonsense 2 years parts and labour guarantee - backed up by Worcester Total Cover, an optional complete maintenance scheme, to keep your boiler operating at peak condition and efficiency. To find out more about Worcester, Bosch Group log on to www.worcester-bosch.co.uk .
  • Page 4: Safety Precautions

    Any misuse or unauthorised modifications to the boiler, flue or associated components and systems could invalidate the warranty. The manufacturer accepts no liability arising from any such actions. This does not affect your statutory rights. GREENSTAR Ri SAFETY PRECAUTIONS 8 716 115 172a (06/2008)
  • Page 5: General Notes

    GENERAL NOTES SERVICING The boiler must be serviced regularly by a competent, qualified person, such as a Worcester service engineer or alternatively a British Gas or other CORGI registered person. Always use original spares, to help maintain the economy, safety and reliability of the boiler and to have the Service Record completed in the Benchmark checklist.
  • Page 6 This pipe must not be blocked or requirements of BS2767:10. altered in any way. GENERAL NOTES GREENSTAR Ri 8 716 115 172a (04/2008)
  • Page 7 24 hours the boiler will run the system pump for a few seconds to reduce the possibility of pump seizure during long periods of inactivity, which is usually more frequent during the summer months. SAFETY PRECAUTIONS GREENSTAR Ri 8 716 115 172a (06/2008)
  • Page 8: Controls

    1. MAIN POWER “OFF/ON” KNOB 2. CENTRAL HEATING TEMPERATURE CONTROL KNOB IMPORTANT: DO NOT PRESS THE INDICATOR LIGHT TO RESET THE BOILER 3. INDICATOR/DIAGNOSTICS LIGHT “MAINS ON/OFF” (BLUE) 4. BURNER “ON” INDICATOR LIGHT (GREEN) CONTROLS GREENSTAR Ri 8 716 115 172a (06/2008)
  • Page 9: Operating The Boiler

    If remote pipework is exposed to low temperatures, ensure that the installer has added a frost thermostat. 35°C 82°C OPERATING THE BOILER GREENSTAR Ri 8 716 115 172a (06/2008)
  • Page 10: Fault Condition

    Reset the boiler as described above. If the fault remains and cannot be cleared: Call Worcester, Bosch Group for assistance, giving a description of the fault and, if possible the fault flashing sequence from the mains indicator.
  • Page 11: Maintaining Your Boiler

    If you would like to know more about a Worcester, Bosch Group service contract, please tick the appropriate box on your warranty registration card.
  • Page 12: Fault Or Breakdown

    FAULT OR BREAKDOWN This boiler is supported in the UK and Ireland by Worcester, Bosch Group, part of Bosch Thermotechnology Ltd. Specially trained, Worcester, Bosch Group Service Engineers are available to attend a breakdown occurring on this boiler. No charge will be made for parts and/or labour providing: A boiler fault is found and the boiler has been installed within the past 24 months.
  • Page 13: General Operating Notes

    If you decide to turn off radiators in unused rooms, spare bedrooms etc., you may experience slightly lower room temperatures in rooms next to unheated rooms. TIPS ON ENERGY SAVING GREENSTAR Ri 8 716 115 172a (06/2008)
  • Page 14: Your Guarantee

    The boiler has been used only for normal domestic purposes for which it was designed. This guarantee applies only to equipment purchased and used in the United Kingdom and Eire. This guarantee does not affect your statutory rights. YOUR GUARANTEE GREENSTAR Ri 8 716 115 172a (06/2008)
  • Page 15: Guarantee Registration

    Registration Card within 30 days of purchase. Returning the card will register you as the owner of your new Greenstar Ri boiler and will assist us in maintaining an effective and efficient customer service by establishing a reference and permanent record for your boiler.
  • Page 16: Dedicated To Heating Comfort

    USER INSTRUCTIONS & CUSTOMER CARE GUIDE Dedicated to heating comfort Worcester, Bosch Group Cotswold Way, Warndon, Worcester WR4 9SW. Tel. 01905 754624 Fax. 01905 754619 www.worcester-bosch.co.uk Worcester Bosch Group is a brand name of Bosch Thermotechnology Ltd. 8 716 115 172a (06/2008)

Table of Contents