Inspection and maintenance
Adjusting the minimum rated output settings
With the appliance in minimum rated output.
▶ Remove the seal from the adjusting screw of the gas valve and set the
CO
content for minimum rated output.
2
1
Fig. 88 Setting the CO2 content
[1]
Gas valve - NG
▶ Re-check settings at maximum and minimum rated output and re-
adjust if required.
▶ Seal the gas valve minimum adjustment.
▶ Exit the chimney sweep mode.
▶ Enter the CO
contents in the servicing record.
2
9.13

Cleaning the rainguard

Disassemble the rainguard
Fig. 89 Disassembly of the water drain hose
[1]
Water drain hose
60
MIN. %
T40
0010047830-001
1
0010046065-001
▶ Remove the water drain hose [1] from the rainguard.
1
2
3
Fig. 90 Disassembly of the flue kit and the flue adaptor
[1]
Screws
[2]
Flue kit and flue adaptor
[3]
Rainguard
▶ Loosen three screws [1] (hexagon or philips) with a screw driver.
▶ Remove the flue kit and the flue adaptor[2].
Fig. 91 Disassembly of the rainguard
[1]
Rainguard
▶ Pull down the rainguard [1] and take it out.
Greenstar 1000 – 6721835943 (2023/08)
0010046066-002
1
0010046067-001