Functions
7.7 Expanded I/O Option
1010N-7 Expanded I/O Module Option
The Expanded I/O Module Option provides all of the above plus the following outputs:
● The four signals that drive the pulse generator outputs (Pgen1 and Pgen2) and voltage
● By spanning and assigning a system variable to 0-10 volt (Vo1 and Vo2) or 0-5000 Hz
Table 7- 6
Channel
CH1
CH2
Note
The four Aux Io outputs are externally powered.
122
outputs (Vo1 and Vo2) of the flow meter create four current outputs: Aux Io1, Aux Io2,
Aux Io3 and Aux Io4 (see diagram).
pulse output (Pgen1 and Pgen2) the module simultaneously outputs these signals to the
Expanded I/O Module Option Aux outputs. For a 2-Channel flow meter the programming
assignments are as follows:
Typical 2-Channel Flow Meter Expanded I/O Option Connections
Signal
Pgen1
Vo1
Pgen2
Vo2
AUX Io
Io1
Io3
Io2
Io4