Codes - Trane S8V2A040M3PC Installation, Operation And Maintenance Manual

Link communicating or 24 volt gas-fired 2 stage induced draft furnaces with variable speed motor
Table of Contents

Advertisement

Integrated Furnace Control Display Codes
ORN
err
L6F
Cr
MNR
C0d
ODE
0du
C0f
CPC
CPH
Xod
!sd
gXC
SAE
RAE
RSP
run
Alarm Error Code
e0!
e2.!
e2.2
e2.3
e3.!
e3.2
e3.3
e3.4
e04
e4.1
e4.2
e05
e6.1
e6.2
e6.3
e7.!
56
Menu Options
Orientation
Active Alarm Menu
Last 6 Faults (To clear – Hold Option button down for 5 seconds after entering the L6F menu)
Code Release Number
Model Number Recovery
Cooling Off Delay (Seconds)
Outdoor Tonnage
Outdoor Unit Type (Single / Two Stage)
Blower Constant Fan Airflow Multiplier %
Cooling (CFM/Ton)
Heat Pump Heating (CFM/Ton)
Heat Off Delay (Seconds)
Inter-Stage Delay (Seconds)
Gas Heating CFM (Airflow x10)
Supply Air Temperature
Return Air Temperature
Return Static Pressure
Run Test Mode
Error Codes
Alarm Explanation
Loss of the IRQ or other internal IFC failures
Retries exceeded (Flame never sensed, one hour lockout after 7 times)
Recycles exceeded (Flame sensed then lost, one hour lockout after 10 times)
1st stage gas valve not energized when it should be (10 times)
Shorted pressure switch, 1st stage
Open pressure switch, 1st stage
Shorted pressure switch, 2nd stage
Open pressure switch, 2nd stage
Open high limit switch
Open reverse air-flow limit switch
Open roll-out limit switch
Flame detected when it should not be present
Voltage reversed polarity
Bad grounding
(1) Igniter open or igniter relay failure on IFC
(2) Igniter relay failure on IFC
1st stage gas valve energized without request
S8V2-SVX001-1A-EN