Combustion And Input Check - Trane S8V2A040M3PC Installation, Operation And Maintenance Manual

Link communicating or 24 volt gas-fired 2 stage induced draft furnaces with variable speed motor
Table of Contents

Advertisement

F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n
I I m m p p o o r r t t a a n n t t : : If local codes allow the use of flexible gas
appliance connector, always use a new
listed connector. Do not use a connector
which has previously serviced another gas
appliance.
Refer to the piping table for delivery sizes. Connect gas
supply to the unit, using a ground joint union and a
manual shut-off valve. National codes require a
condensation drip leg to be installed ahead of the gas
valve.
The furnace and its individual shut-off valve must be
disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 1/2 psig (3.5 kPa).
The furnace must be isolated from the gas supply
piping by closing its individual manual shut-off valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig
(3.5 kPa).
N N o o t t e e : : Maximum pressure to the gas valve for natural
gas is 13.8" W.C. Minimum pressure is 5.0" W.C.
Maximum pressure to the gas valve for propane
is 13.8" W.C. Minimum pressure is 11.0" W.C.
NATURAL GAS ONLY
TABLE OF CUBIC FEET PER HOUR OF GAS
FOR VARIOUS PIPE SIZES AND LENGTHS
PIPE
LENGTH OF PIPE
SIZE
10
20
30
1/2
131
90
3/4
273
188
151
1
514
353
284
1–1/4
1060
726
583
This table is based on Pressure Drop of 0.3 inch W.C. and 0.6 SP.
GR. Gas
All gas fittings must be checked for leaks using a soapy
solution before lighting the furnace. D D O O N N O O T T C C H H E E C C K K
W W I I T T H H A A N N O O P P E E N N F F L L A A M M E E ! !
For propane conversions on all other S-Series
Furnaces, use BAYLPSS400* conversion kit with
stainless steel burners.
ORIFICE SIZES
INPUT
NUMBER OF
RATING
BURNERS
BTUH
40,000
2
60,000
3
80,000
4
100,000
5
120,000
6
28
40
50
60
72
62
55
50
129
114
104
243
215
195
499
442
400
MAIN BURNER ORIFICE
DRILL SIZE
PROPANE
NAT. GAS
GAS
45
56
45
56
45
56
45
56
45
56

Combustion and Input Check

1. Make sure all gas appliances are off except the
furnace.
2. Clock the gas meter with the furnace operating
(determine the dial rating of the meter) for one
revolution.
3. Match the "Sec" column in the gas flow table with
the time clocked.
4. Read the "Flow" column opposite the number of
seconds clocked.
5. Use the following factors if necessary:
a. For 1 Cu. Ft. Dial Gas Flow CFH = Chart Flow
Reading ÷ 2
b. For 1/2 Cu Ft. Dial Gas Flow CFH = Chart Flow
Reading ÷ 4
c. For 5 Cu. Ft. Dial Gas Flow CFH = 10X Chart Flow
Reading ÷ 4
6. Multiply the final figure by the heating value of the
gas obtained from the utility company and compare
to the nameplate rating. This must not exceed the
nameplate rating.
Sec.
Flow
10
732
70
11
666
46
12
610
95
13
563
179
14
523
368
15
488
16
458
17
431
18
407
19
385
20
366
21
349
22
333
23
318
24
305
25
293
26
282
27
271
28
262
29
253
30
244
Gas Flow in Cubic Feet Per Hour
2 Cubic Foot Dial
Sec.
Flow
Sec.
Flow
31
236
52
141
32
229
53
138
33
222
54
136
34
215
55
133
35
209
56
131
36
203
57
128
37
198
58
126
38
193
59
124
39
188
60
122
40
183
62
118
41
179
64
114
42
174
66
111
43
170
68
108
44
166
70
105
45
163
72
102
46
159
74
99
47
156
76
96
48
153
78
94
49
149
80
92
50
146
82
89
51
144
84
87
S8V2-SVX001-1A-EN
Sec.
Flow
86
85
88
83
90
81
94
78
98
75
100
73
104
70
108
68
112
65
116
63
120
61
130
56
140
52
150
49
160
46
170
43
180
41
190
39
200
37

Hide quick links: