Fault Code Recovery - Trane S8V2A040M3PC Installation, Operation And Maintenance Manual

Link communicating or 24 volt gas-fired 2 stage induced draft furnaces with variable speed motor
Table of Contents

Advertisement

e7.2
e08
e11
e12
e13
e14
e17
e23
e24
e25
e26
e27
e28

Fault Code Recovery

F F a a u u l l t t C C o o d d e e R R e e c c o o v v e e r r y y
1. To view the last 6 faults, press the "Menu" key until
the "Last 6 Faults" (L6F) menu appears.
2. Enter the menu by pressing the "Option" key.
3. The last 6 faults can be viewed.
C C l l e e a a r r i i n n g g t t h h e e L L a a s s t t 6 6 F F a a u u l l t t s s
1. To clear the last 6 faults, press the "Menu" key until
the "Last 6 Faults" (L6F) menu appears.
2. Enter the menu by pressing the "Option" key.
S8V2-SVX001-1A-EN
Redundant relay (HLO output) energized when it should not be
Low flame sense. Current is low but strong enough for operation
(1) 1st stage gas valve not energized when it should be
(2) 2nd stage gas valve energized without request
(3) 2nd stage gas valve not energized when it should be
(4) Gas valve relay stuck closed
Open fuse
Blower HP or OEM ID do not match furnace
Configuration file error
Blower communication error
Menu parameters not received by CCM
Internal communication error between the ACM and CCM
Orientation sensor out of bounds
1) Return static pressure transducer out of bounds
2) Return static pressure transducer configured but not connected
1) Return air thermistor out of bounds
2) Return air thermistor configured but not connected
1) Supply air thermistor out of bounds
2) Supply air thermistor configured but not connected
I I n n t t e e g g r r a a t t e e d d F F u u r r n n a a c c e e C C o o n n t t r r o o l l D D i i s s p p l l a a y y C C o o d d e e s s
3. Hold the "Option" key for at least 5 seconds.
4. Release and a set of 3 dashes with be seen 3 times.
This confirms the faults have been cleared.
R R e e s s e e t t t t i i n n g g F F a a c c t t o o r r y y D D e e f f a a u u l l t t s s
1. Display must be in Idle Mode.
2. Push the "Menu" and "Option" buttons at the same
time for 15 seconds then release.
3. The 7 segment will flash "FD" 3 times. This confirms
the unit has been reset to the factory defaults.