P P r r o o d d u u c c t t S S p p e e c c i i f f i i c c a a t t i i o o n n
Model
Type
RATINGS
(b)
1st Stage Input BTUH
1st Stage Capacity BTUH (ICS)
2nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS)
1st Stage Temp. Rise (Min. - Max.) °F
2nd Stage Temp. Rise (Min. - Max.) °F
AFUE – Rating
(c)
Return Air Temp. (Min. - Max.) °F
BLOWER DRIVE
Diameter - Width (in.)
No. Used
Speeds (No.)
(d)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
FLA
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts/Ph/Hz
FLA
Inducer Orifice
FILTER - Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT PIPE DIAMETER - Min. (in.)
HEAT EXCHANGER - Type
Gauge (Fired)
ORIFICES - Main
Nat. Gas Qty. - Drill Size
L.P. Gas Qty. - Drill Size
GAS VALVE
PILOT SAFETY DEVICE - Type
BURNERS - QTY
POWER CONN. - V/Ph/HZ
(e)
Ampacity (Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
(a)
Central Furnace heating designs are certified to ANSI Z21.47 - latest edition.
For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
(b)
(c)
Based on U.S. government standard tests.
(d)
Direct drive variable speed blower motor is an ECM constant airflow blower motor.
(e)
The above wiring specifications are in accordance with National Electric Code, however, installations must comply with local codes.
10
S8V2C080M5PC
S8V2C080M5PD
Upflow / Horizontal / Downflow
52,000
41,800
80,000
(c)
64,800
30 - 60
30 - 60
80
55°F - 80°F
DIRECT
11 X 11
1
Variable
See Fan Performance Table
1
Variable
120 / 1 / 60
10
PSC
Direct - 2
3300/2700
120 / 1 / 60
0.30
1.80
No
High Velocity
1 - 20 X 25 - 1 in.
4 Round
Aluminized Steel
20 - 19
4 - 45
4 - 56
Redundant - Two Stage
120 V SiNi Igniter
4
120 / 1 / 60
13
15
1/2
(a)
S8V2C100M5PC
(a)
S8V2C100M5PD
Upflow / Horizontal / Downflow
65,000
52,300
100,000
81,200
25 - 55
30 - 60
80
55°F - 80°F
DIRECT
11 X 11
1
Variable
See Fan Performance Table
1
Variable
120 / 1 / 60
10
PSC
Direct - 2
3200/2900
120 / 1 / 60
0.33
2.50
No
High Velocity
1 - 20 X 25 - 1 in.
4 Round
Aluminized Steel
20 - 19
5 - 45
5 - 56
Redundant - Two Stage
120 V SiNi Igniter
5
120 / 1 / 60
13
15
1/2
(a)
S8V2D120M5PC
(a)
S8V2D120M5PD
Upflow / Horizontal /
Downflow
84,000
67,900
120,000
98,000
30 - 60
35 - 65
80
55°F - 80°F
DIRECT
11 X 11
1
Variable
See Fan Performance Table
1
Variable
120 / 1 / 60
10
PSC
Direct - 2
3200/2900
120 / 1 / 60
0.33
2.15
No
High Velocity
1 - 24 X 25 - 1 in.
4 Round
Aluminized Steel
20 - 19
6 - 45
6 - 56
Redundant - Two Stage
120 V SiNi Igniter
6
120 / 1 / 60
13
15
1/2
S8V2-SVX001-1A-EN
(a)
(a)