Codes - Trane L8V1A040U3VSBA Installation, Operation And Maintenance Manual

Upflow/horizontal left/right gas-fired, single stage induced draft furnace with variable speed blower motor
Table of Contents

Advertisement

Integrated Furnace Control Display Codes
IdL
XtI
aRF
C0F
CLI
CL2
Xp!
Xp2
dFt
err
L6F
Cr
C0d
0dt
0du
COF
CpC
CpH
Xod
!sd
gXC
run
Table 16. Fault Code Recovery
Fault Code Recovery
1.
To view the last 6 faults, press the "Menu" key until the "Last 6
Faults" (L6F) menu appears.
2.
Enter the menu by pressing the "Option" key.
3.
The last 6 faults can be viewed.
Clearing the Last 6 Faults
1.
To clear the last 6 faults, press the "Menu" key until the "Last 6
Faults" (L6F) menu appears.
2.
Enter the menu by pressing the "Option" key.
3.
Hold the "Option" key for at least 5 seconds.
4.
Release and a set of 3 dashes with be seen 3 times. This confirms
the faults have been cleared.
Resetting Factory Defaults
1.
Display must be in Idle Mode.
2.
Push the "Menu" and "Option" buttons at the same time for 15
seconds then release.
3.
The 7 segment will flash "FD" 3 times. This confirms the unit has
been reset to the factory defaults.
L8V1-SVX001-1A-EN
Inducer with ECM Blower Motor
Idle
Gas Heating
Calculated Airflow (Followed by Airflow times 10)
Continuous Fan
First Stage Cooling
Second Stage Cooling
First Stage Heat Pump
Second Stage Heat Pump
Defrost Mode
Menu Options
Active Alarm Menu
Last 6 Faults (To clear — Hold Option button down for 5 seconds)
Code Release Number
Cooling Off Delay (Seconds)
Outdoor Tonnage
Outdoor Unit
Blower Constant Fan Airflow Multiplier (Percentage)
Cooling (CFM/Ton)
Heat Pump Heating (CFM/Ton)
Heat Off Delay (Seconds)
Inter-Stage Delay (Seconds)
Gas Heating CFM (Airflow times 10)
Run Test Mode
IFC Component Layout
E32
4 N/A
Inducer 3-Phase
3 IND-(U)
2 IND-(V)
1 IND-(W)
E12
1 12V
2 RX
Motor
Communications
3 GND
4 TX
Menu Option
MENU
E14
12 N/A
OPTION
11 HLI
10 MVH
9 MVL
8 GND
7 N/A
GND 3
6 TH
PI 2
VCC 1
5 MVC
4 HLO
3 N/A
2 TR
1 N/A
5 AMP
Low Votage Fuse
BK JUMPER
BK Jumper
Flame Sense
Line
E23
LINE
Neutral
E25
E26
E39
1
2
3
FP
Seven Segment LED
E5
N 1
Igniter
PERSONALITY
H 2
MODULE
E18
Personality Module
3
2
Pressure Transducer
1
EAC
EAC
IFC
HUM
HUM
Y1 - O Jumper
BK N/A W1
R
G
B/C
Y2
Y1
O
45