Locations And Clearances - Trane S8V2A040M3PC Installation, Operation And Maintenance Manual

Link communicating or 24 volt gas-fired 2 stage induced draft furnaces with variable speed motor
Table of Contents

Advertisement

F F u u r r n n a a c c e e I I n n s s t t a a l l l l a a t t i i o o n n G G u u i i d d e e l l i i n n e e s s
require any special provisions for venting other than
what is indicated in these instructions.
W W a a r r n n i i n n g g : : T T h h e e s s e e f f u u r r n n a a c c e e s s a a r r e e n n o o t t a a p p p p r r o o v v e e d d o o r r
i i n n t t e e n n d d e e d d f f o o r r i i n n s s t t a a l l l l a a t t i i o o n n i i n n m m a a n n u u f f a a c c t t u u r r e e d d ( ( m m o o b b i i l l e e ) )
h h o o u u s s i i n n g g , , t t r r a a i i l l e e r r s s , , o o r r r r e e c c r r e e a a t t i i o o n n a a l l v v e e h h i i c c l l e e s s . .

Locations and Clearances

The location of the Furnace is normally selected by the
architect, the builder, or the installer.
Minimum clearance to combustible materials
3. Is there sufficient space for servicing the Furnace
and other equipment? A minimum of 24 inches
front accessibility to the Furnace must be provided.
Any access door or panel must permit removal of
the largest component.
4. Are there at least 3 inches of clearance between the
Furnace combustion air openings in the front panel
and any closed panel or door provided?
5. Are the ventilation and combustion air openings
large enough and will they remain unobstructed? If
outside air is used, are the openings set 12" above
the highest snow accumulation level?
6. Allow sufficient height in supply plenum above the
Furnace to provide for cooling coil installation, if
the cooling coil is not installed at the time of this
Furnace installation.
12
However, before the Furnace is moved into place, be
sure to consider the following requirements:
1. Is the location selected as near the chimney or vent
and as centralized for heat distribution as practical?
2. Do all clearances between the Furnace and
enclosure equal or exceed the minimums stated in
Clearance Table below?
7. The Furnace shall be installed so electrical
components are protected from water.
8. A vertical downflow furnace without a coil, must
use BAYBASE205 when installed on combustible
flooring.
9. If the Furnace is installed in a garage, it must be
installed so that the burners, and the ignition
source are located not less than 18 inches above the
floor and the Furnace must be located or protected
to avoid physical damage from vehicles.
10. The gas furnace must not be located where
excessive exposure to contaminated combustion
air will result in safety and performance related
problems. Avoid the following known
contaminants:
a. Permanent wave solutions
S8V2-SVX001-1A-EN