Options - Trane S8V2A040M3PC Installation, Operation And Maintenance Manual

Link communicating or 24 volt gas-fired 2 stage induced draft furnaces with variable speed motor
Table of Contents

Advertisement

Furnace Combustion Air Exhaust Options
Note: Default is left side for electric and gas connections.
The following sections give instructions for the
different furnace orientations and the options for
venting the exhaust combustion air.
Table 19. Venting Options for Upflow Applications
Refer to the illustrations below to find the approved venting options for upflow furnace.
Important: The exhaust must be vented to the outdoors.
Vented out top.
Table 20. Venting Options for Horizontal Left Applications
Refer to the illustrations below to find the approved venting options for horizontal left furnace.
Important: The exhaust must be vented to the outdoors.
Note: 4" Type B double wall vent pipe must be used inside of the furnace cabinet.
Vented out top.
S8V2-SVX001-1A-EN
I I m m p p o o r r t t a a n n t t : : When looking at the different orientations,
Upflow Orientation or Installation
Vented through left side.
Horizontal Left Orientation or Installation
the direction of the combustion air exhaust
in the illustration's description is after the
furnace has been rotated, if needed.
Vented through right side.
Vented through left side.
49