5
5.4 Air filter check
Importante
• Before proceeding with operation, read
NOTE: Components not necessarily supplied by KOHLER.
1. Release the two clasps F of the cover A.
2. Remove the cartridge B.
3. Clean the inside components A and D with a damp cloth.
4. Do not use compressed air , repeatedly tap the front side E on
a flat surface.
5. Reinstall:
cartridge B.
the cover A checking the right tightness of clasps F.
5.5 Check of the radiator heat - exchanger surface
Danger
• For safety precautions see
NOTE: Component not necessarily supplied by KOHLER.
Important
• Before proceeding with operation, read
• Wear safety goggles when using compressed air.
•
The radiator heat-exchange surface must be cleaned on both.
1. Check the radiator heat-exchange surface D.
2. Clean the surface with a brush soaked in special detergent if it
is clogged.
EN
32
INFORMATION ABOUT MAINTENANCE
Chap.
3.
Par.
3.2.2.
Par.
3.2.2.
Fig 5.3